Peak fitting to resolve CN- isotope ratios in biological and environmental samples using TOF-SIMS

被引:7
作者
Cliff, JB
Gaspar, DJ
Bottomley, PJ
Myrold, DD
机构
[1] Oregon State Univ, Dept Crop & Soil Sci, Corvallis, OR 97331 USA
[2] Pacific NW Natl Lab, Environm & Mol Sci Lab, Richland, WA 99352 USA
关键词
TOF-SIMS; environmental; nitrogen; peak fitting; biological;
D O I
10.1016/j.apsusc.2004.03.169
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Our research has focused on developing TOF-SIMS to measure organic N-15 in environmental samples [Appl. Environ. Microbiol. 68 (8) (2002) 4067]. Our goal was to develop a peak-fitting algorithm that would successfully remove the isobaric interferences of Al- and (CN-)-C-13-N-14 from (CN-)-C-12-N-15 ions under conditions of low mass resolution inherent in environmental samples. We tested a variety of peak-fitting models and found that the EMG + GMG (E + G) model performed better than the standard peak shape shifting method under conditions of high mass resolution, unless Al- was present as an interference. Under conditions of Al- interference and low N-15 content, the standard method performed better than the E + G model. As N-15 content increased, the E + G model worked comparably or better than the standard method. Limited mass resolution during analysis of organic N-15 standards on kaolin clay dictated using the standard method which performed acceptably on standards containing greater than 1 at.% N-15. These data emphasize the potential utility of using analytical models to resolve isobaric interferences in TOF-SIMS. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:912 / 916
页数:5
相关论文
共 9 条
[1]   COMPUTER RESOLUTION OF UNRESOLVED CONVOLUTED GAS-CHROMATOGRAPHIC PEAKS [J].
ANDERSON, AH ;
GIBB, TC ;
LITTLEWO.AB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1970, 8 (11) :640-&
[2]  
BATES DM, 1988, NONLINEAR REFRESSION
[3]   Exploration of inorganic C and N assimilation by soil microbes with time-of-flight secondary ion mass spectrometry [J].
Cliff, JB ;
Gaspar, DJ ;
Bottomley, PJ ;
Myrold, DD .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (08) :4067-4073
[4]   Mathematical functions for the representation of chromatographic peaks [J].
Di Marco, VB ;
Bombi, GG .
JOURNAL OF CHROMATOGRAPHY A, 2001, 931 (1-2) :1-30
[5]   Isotopic ratio measurements by time-of-flight secondary ion mass spectrometry [J].
Fahey, AJ ;
Messenger, S .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :227-242
[6]   CURVE-FITTING FOR RESTORATION OF ACCURACY FOR OVERLAPPING PEAKS IN GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY [J].
GOODMAN, KJ ;
BRENNA, JT .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :1294-1301
[7]   TOF-SIMS in cosmochemistry [J].
Stephan, T .
PLANETARY AND SPACE SCIENCE, 2001, 49 (09) :859-906
[8]   CORRECTION OF DEAD-TIME EFFECTS IN TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
STEPHAN, T ;
ZEHNPFENNING, J ;
BENNINGHOVEN, A .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1994, 12 (02) :405-410
[9]  
*SYSTAT SOFTW INC, 2002, PEAKFIT US MAN