Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty

被引:83
作者
Bäthis, H
Perlick, L
Tingart, M
Lüring, C
Perlick, C
Grifka, J
机构
[1] Univ Regensburg, Dept Orthopaed Surg, D-93042 Regensburg, Germany
[2] Aarhus Univ Hosp, Aarhus Kommune Hosp, Dept Orthopaed, DK-8000 Aarhus C, Denmark
关键词
D O I
10.1007/s00264-003-0533-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Restoration of the mechanical limb axis and accurate component orientation are two major factors affecting the long-term results after total knee replacement (TKR). Different navigation systems are available to improve the outcome. Image-based systems require preoperative CT scans, while non-image-based systems gain all necessary information intra-operatively during a registration process. We studied 130 patients who received a TKR either using the CT-based (Knee 1.1) or the CT-free module (CT-free Knee 1.0) of the BrainLAB Vector-Vision Navigation System. Post-operative leg alignment and component orientation was determined on long-leg coronal and lateral X-rays. Sixty of 65 patients in the CT-based group and 63/65 patients in the CT-free group had a post-operative leg axis between 3degrees varus/valgus. No significant differences were found for varus/valgus orientation of the femoral and tibial components.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 17 条
[1]  
BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
[2]  
DELP SL, 1998, CLIN ORTHOP RELAT R, V354, P49
[3]   TOTAL CONDYLAR KNEE ARTHROPLASTY - PROSTHETIC COMPONENT POSITIONING AND RADIOLUCENT LINES [J].
HVID, I ;
NIELSEN, S .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02) :160-165
[4]   CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[5]  
JENNY JY, 2003, P 70 ANN M AAOS AM A, P96
[6]   Instrumentation pitfalls - You just can't go on autopilot! [J].
Laskin, RS .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :18-22
[7]   INFLUENCE OF POSITIONING OF PROSTHESIS IN TOTAL KNEE REPLACEMENT [J].
LOTKE, PA ;
ECKER, ML .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) :77-79
[8]   The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties [J].
Mahaluxmivala, J ;
Bankes, MJK ;
Nicolai, P ;
Aldam, CH ;
Allen, PW .
JOURNAL OF ARTHROPLASTY, 2001, 16 (05) :635-640
[9]   Navigation in knee arthroplasty - Preliminary clinical experience and prospective comparative study in comparison with conventional technique [J].
Mielke, RK ;
Clemens, U ;
Lens, JH ;
Kershally, S .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (02) :109-116
[10]   Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty [J].
Novotny, J ;
Gonzalez, MH ;
Amirouche, FML ;
Li, YC .
JOURNAL OF ARTHROPLASTY, 2001, 16 (05) :641-647