Compact CH4 sensor based on difference frequency mixing of diode lasers in quasi-phasematched LiNbO3

被引:41
作者
Lancaster, DG
Weidner, R
Richter, D
Tittel, FK
Limpert, J
机构
[1] Rice Univ, Rice Quantum Inst, Dept Elect & Comp Engn, Houston, TX 77005 USA
[2] Univ Jena, Inst Angew Phys, D-6900 Jena, Germany
基金
美国国家科学基金会; 美国国家航空航天局;
关键词
difference frequency generation; molecular spectroscopy; trace gas detection; methane;
D O I
10.1016/S0030-4018(00)00485-5
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A compact, portable and robust room temperature CH4 sensor is reported. By difference frequency mixing a 500 mW alpha-DFB diode laser at 1066 nm and an erbium-doped fiber amplified 1574 nm DFB diode laser in periodically poled lithium niobate up to 7 mu W of narrowband radiation at 3.3 mu m is generated. Real-time monitoring of CH4 over a 7 day period using direct absorption in an open-path multipass cell (L = 36 m) demonstrates a detection precision of +/- 14 ppb. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:461 / 468
页数:8
相关论文
共 11 条
[1]   Mid-infrared difference-frequency generation source pumped by a 1.1-1.5-μm dual-wavelength fiber amplifier for trace-gas detection [J].
Goldberg, L ;
Koplow, J ;
Lancaster, DG ;
Curl, RF ;
Tittel, FK .
OPTICS LETTERS, 1998, 23 (19) :1517-1519
[2]   Temperature-dependent Sellmeier equation for the index of refraction, n(e), in congruent lithium niobate [J].
Jundt, DH .
OPTICS LETTERS, 1997, 22 (20) :1553-1555
[3]   Portable fiber-coupled diode-laser-based sensor for multiple trace gas detection [J].
Lancaster, DG ;
Richter, D ;
Tittel, FK .
APPLIED PHYSICS B-LASERS AND OPTICS, 1999, 69 (5-6) :459-465
[4]   Real-time measurements of trace gases using a compact difference-frequency-based sensor operating at 3.5 μm [J].
Lancaster, DG ;
Richter, D ;
Curl, RF ;
Tittel, FK .
APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03) :339-345
[5]   Fibre coupled difference frequency generation utilising ytterbium-doped fibre amplifier and periodically poled LiNbO3 [J].
Lancaster, DG ;
Goldberg, L ;
Koplow, J ;
Curl, RF ;
Tittel, FK .
ELECTRONICS LETTERS, 1998, 34 (13) :1345-1347
[6]   Detection of CO in air by diode-pumped 4.6-mu m difference-frequency generation in quasi-phase-matched LiNbO3 [J].
Petrov, KP ;
Goldberg, L ;
Burns, WK ;
Curl, RF ;
Tittel, FK .
OPTICS LETTERS, 1996, 21 (01) :86-88
[7]  
Sass R., 1992, ECOL, P199
[8]   METHANE EMISSIONS FROM RICE FIELDS - EFFECT OF SOIL PROPERTIES [J].
SASS, RL ;
FISHER, FM ;
LEWIS, ST ;
JUND, MF ;
TURNER, FT .
GLOBAL BIOGEOCHEMICAL CYCLES, 1994, 8 (02) :135-140
[9]   SLOWING DOWN OF THE GLOBAL ACCUMULATION OF ATMOSPHERIC METHANE DURING THE 1980S [J].
STEELE, LP ;
DLUGOKENCKY, EJ ;
LANG, PM ;
TANS, PP ;
MARTIN, RC ;
MASARIE, KA .
NATURE, 1992, 358 (6384) :313-316
[10]   Room-temperature mid-infrared laser sensor for trace gas detection [J].
Topfer, T ;
Petrov, KP ;
Mine, Y ;
Jundt, D ;
Curl, RF ;
Tittel, FK .
APPLIED OPTICS, 1997, 36 (30) :8042-8049