A new possible interpretation of the anomalous fading in thermoluminescent materials as normal fading in disguise

被引:24
作者
Chen, R
HagYahya, A
机构
[1] School of Physics and Astronomy, Raymond Beverly Sackler Fac. E., Tel-Aviv University, Tel-Aviv
关键词
D O I
10.1016/S1350-4487(96)00147-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A new possible explanation is given to the anomalous fading of thermoluminescence (TL), observed in some materials. It is suggested that anomalous fading may, in some cases, be normal fading in disguise. The existence of non-radiative centers which are competing with the radiative luminescence center may cause the occurrence of a very narrow TL peak. The apparent kinetics parameters, say E-app and s(app) in first order kinetics, may appear to be much larger than the real values due to the narrowing of the peak. This, in turn, results in the expectation of a very long decay time, tau(app), at, for example, room temperature. The real values of the parameters are, however, such that the loss of trapped carriers is orders of magnitude faster. The details of the model are given in terms of rate equations, as well as examples of numerical solutions during excitation followed by relaxation and then heating during the read-out phase. From these, the effective expected lifetimes were up to five orders of magnitude larger than that of the observable effect, which can explain; at least in some cases, the anomalous fading. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 12 条
[1]  
BLAIR IM, 1972, 3 LUN SCI C, V3, P2949
[2]   THE LUMINESCENCE OF DIAMONDS [J].
BULL, C ;
GARLICK, GFJ .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1950, 63 (371) :1283-1291
[3]   Interpretation of very high activation energies and frequency factors in TL as being due to competition between centres [J].
Chen, R ;
HagYahya, A .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :17-20
[4]   ON CALCULATION OF ACTIVATION ENERGIES AND FREQUENCY FACTORS FROM GLOW CURVES [J].
CHEN, R .
JOURNAL OF APPLIED PHYSICS, 1969, 40 (02) :570-&
[5]  
Garlick G.F.J., 1972, S INT ASTRON UNION, V47, P324
[6]  
Hoogsenstraten W, 1958, Philips Res. Rep., V13, P515
[7]   IS ISOTHERMAL DEFERRED LUMINESCENCE IN ORGANIC GLASSES DUE TO ELECTRON TUNNELLING [J].
KIEFFER, F ;
MEYER, C ;
RIGAUT, J .
CHEMICAL PHYSICS LETTERS, 1971, 11 (03) :359-&
[8]   ANOMALOUS FADING OF CAF2-MN THERMOLUMINESCENT DOSIMETERS [J].
SCHULMAN, JH ;
GINTHER, RJ ;
GORBICS, SG ;
NASH, AE ;
WEST, EJ ;
ATTIX, FH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1969, 20 (07) :523-&
[9]   TUNNELING AFTERGLOW AND ANOMALOUS FADING IN DOSIMETRY WITH CASO4-DY [J].
VISOCEKAS, R ;
OUCHENE, M ;
GALLOIS, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3) :553-555
[10]   ANOMALOUS FADING OF THERMOLUMINESCENCE IN MINERAL SAMPLES [J].
WINTLE, AG .
NATURE, 1973, 245 (5421) :143-144