Selective determination of airborne hexavalent chromium using inductively coupled plasma mass spectrometry

被引:67
作者
Li, YR [1 ]
Pradhan, NK [1 ]
Foley, R [1 ]
Low, GKC [1 ]
机构
[1] New S Wales Environm Protect Author, Analyt & Environm Chem Sect, Lidcombe, NSW 1825, Australia
关键词
hexavalent chromium; air; complexation; separation; preconcentration; interconversion; inductively coupled plasma mass spectrometry; dynamic reaction cell; polyatomic interferences;
D O I
10.1016/S0039-9140(02)00196-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for determining ultra-trace levels of hexavalent chromium in ambient air has been developed. The method involves a 24-h sampling of air into potassium hydroxide solution, followed by silica gel column separation of chromium (VI), then preconcentration by complexation and solvent extraction. The chromium (VI) complex was dissolved in nitric acid. The resultant chromium ions were determined by inductively coupled plasma mass spectrometry (ICP-MS) using a dynamic reaction cell (DRC) with ammonia as the reactive gas to reduce polyatomic interferences. The interconversion of chromium in potassium hydroxide solution and air sample matrix were investigated under ambient conditions. It was found that there was no conversion of chromium (VI) into chromium (III) species. However, it was observed that some chromium (III) species were converted into chromium (VI) species. For a KOH solution containing 100 mug l(-1) of chromium (III) species, the rate of conversion was found to be 3% after 24 It exposure, 8% after 48 h, 10% after 72 h and no further conversion was observed thereafter. However, in a solution containing air sample matrix, 9.3% of chromium (III) converted to chromium (VI) within 6 It, and during the course of a 11-day exposure period, 13% (range 8-17%) of chromium (III) converted to chromium (VI). The method detection limit (MDL) for chromium (VI) in potassium hydroxide solution (0.025 M) was found to be 2 x 10(-2) mug l(-1). This is equivalent to 0.2 ng m(-3) (for 23 m(3) air sampled into 200 ml of KOH solution over a 24-h period). The recovery of spiked chromium (VI) from solutions containing air sample matrix was 95 +/- 9% (n = 8). Matrix related interferences were estimated to be less than 10% based on recovery studies. The concentration of airborne chromium (VI) in Sydney residential areas was found to be less than 0.2 ng m(-3), however, in industrial areas the concentrations ranged from 0.2 to 1.3 ng m(-3) using this analytical procedure. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1143 / 1153
页数:11
相关论文
共 35 条
[1]   AUTOMATED VOLTAMMETRIC SYSTEM FOR SHIPBOARD DETERMINATION OF METAL SPECIATION IN SEA-WATER [J].
ACHTERBERG, EP ;
VAN DEN BERG, CMG .
ANALYTICA CHIMICA ACTA, 1994, 284 (03) :463-471
[2]   Preconcentration and speciation of chromium in waters using solid-phase extraction and atomic absorption spectrometry [J].
Adriá-Cerezo, DM ;
Llobat-Estellés, M ;
Maurí-Aucejo, AR .
TALANTA, 2000, 51 (03) :531-536
[3]  
ALAVANJA MCR, 1990, APPL OCCUP ENV HYG, V5, P510
[4]  
[Anonymous], 1998, STANDARD METHODS EXA, V20th, P1
[5]  
[Anonymous], 1996, ALKALINE DIGESTION H
[6]  
[Anonymous], 1996, 7199 USEPA
[7]  
Bartlett R.J., 1988, Chromium in the Natural and Human Environment, P267
[8]   Airborne hexavalent chromium in southwestern Ontario [J].
Bell, RW ;
Hipfner, JC .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (08) :905-910
[9]   PRECONCENTRATION OF CHROMIUM(III) FROM SEA-WATER BY ADSORPTION ON SILICA AND VOLTAMMETRIC DETERMINATION [J].
BOUSSEMART, M ;
VAN DEN BERG, CMG .
ANALYST, 1994, 119 (06) :1349-1353
[10]  
BURKE WA, 2000, MATES, V2, P2