Evaluation of tissue harmonic imaging for the diagnosis of focal liver lesions

被引:47
作者
Tanaka, S
Oshikawa, O
Sasaki, T
Ioka, T
Tsukuma, H
机构
[1] Osaka Med Ctr, Higashinari Ku, Osaka 5378511, Japan
[2] CVD, Osaka 5378511, Japan
关键词
tissue harmonic imaging; hepatocellular carcinoma; liver cirrhosis; liver neoplasm; diagnostic accuracy;
D O I
10.1016/S0301-5629(99)00134-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This was a prospective study to evaluate tissue harmonic imaging (THI) for the diagnosis of focal liver lesions, A total of 15 reviewers read 100 randomly arranged liver images, a fundamental grey-scale image (FGI) and a THI (transmitted: 2 MHz, received: 4 MHz) of each of 50 patients (29 with liver cirrhosis, 42 with focal lesions) taken from the same section. The mean value of overall accuracy for detecting lesions (presence or absence) was significantly higher with THI (82.3%) than with FGI (79.6%) (t = 1.96, p < 0.05). When only the 29 cirrhosis patients were analyzed, the difference was more significant (t = 2.48, p < 0.02). The correct count rate of the number of focal lesions was higher with THI (78.0%) than with FGI (67.0%) (t = 3.61, p < 0.005) in 23 cirrhosis patients with focal lesions. The correct diagnosis of HCC was achieved at a higher rate with THI (42.5%) than with FGI (36.8%), THI was statistically effective for detecting focal lesions, particularly in cirrhotic livers. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:183 / 187
页数:5
相关论文
共 16 条
[1]  
Averkiou MA, 1997, P IEEE ULTR S, V2, P1561
[2]  
BURNS PN, 1992, RADIOLOGY, V185, P142
[3]   Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging [J].
Christopher, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :125-139
[4]  
DESSER TS, 1998, DIAGN IMAGING S, pA18
[5]  
*JAP SOC ULTR MED, 1994, DIAGN CRIT LIV TUM D, P925
[6]   LIVER WITH HYPOECHOIC NODULAR PATTERN AS A RISK FACTOR FOR HEPATOCELLULAR-CARCINOMA [J].
KITAMURA, S ;
IISHI, H ;
TATSUTA, M ;
ISHIKAWA, H ;
HIYAMA, T ;
TSUKUMA, H ;
KASUGAI, H ;
TANAKA, S ;
KITAMURA, T ;
ISHIGURO, S .
GASTROENTEROLOGY, 1995, 108 (06) :1778-1784
[7]   Tissue harmonic imaging sonography: Evaluation of image quality compared with conventional sonography [J].
Shapiro, RS ;
Wagreich, J ;
Parsons, RB ;
Stancato-Pasik, A ;
Yeh, HC ;
Lao, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1203-1206
[8]  
TANAKA S, 1989, CANCER-AM CANCER SOC, V63, P1313, DOI 10.1002/1097-0142(19890401)63:7<1313::AID-CNCR2820630715>3.0.CO
[9]  
2-8
[10]  
TANAKA S, 1986, CANCER, V58, P344, DOI 10.1002/1097-0142(19860715)58:2<344::AID-CNCR2820580224>3.0.CO