Ophthalmic imaging by spectral optical coherence tomography.

被引:248
作者
Wojtkowski, M
Bajraszewski, T
Gorczynska, I
Targowski, P
Kowalczyk, A
Wasilewski, W
Radzewicz, C
机构
[1] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[2] Univ Warsaw, Inst Expt Phys, Warsaw, Poland
[3] Polish Acad Sci, Inst Phys Chem, Warsaw, Poland
关键词
D O I
10.1016/j.ajo.2004.04.049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To demonstrate two novel ophthalmic imaging techniques based on fast Spectral Optical Coherence Tomography (SOCT). DESIGN: Prospective observation case report. METHODS: SETTING: Research laboratory. STUDY POPULATION: A normal human subject. MAIN OUTCOME MEASURES: Correlation of an optical coherence retinal tomogram with known retinal anatomy, reduction of eye exposure to the probing light beam during Optical Coherence Tomography (OCT) examination. RESULTS: High resolution (3- X 20-mum) cross-sec, tional 2-dimensional images of the human retina in vivo have been obtained with only 0.1-second total illumination time (for 1024 A,scans), and approximately 200, muW eye exposure. Details of the optic disk in vivo have been visualized at a rate of eight frames per second, which is sufficient to provide real time analysis. The 3-dimensional images of the optic nerve correspond to the images obtained from a fundus camera. CONCLUSIONS: Because of its short acquisition time and high sensitivity, SOCT uses a 100 times lower exposure/A-scan to obtain images of comparable quality to those obtained by the commercial instrument based on traditional time,domain OCT. Spectral Optical Conherence Tomography therefore provides a much wider safety margin than the traditional method and allows relaxation of the current safety precautions forbidding more than 10 minutes/day scanning of the same location of a retina. As a result of the high speed offered by the new technique, the 3-dimensional tomograms, which allow a surgeon access to a comprehensive and detailed view of relevant pathologies, are obtained in a much shorter, clinically more reasonable time. (C) 2004 by Elsevier Inc. All rights reserved.
引用
收藏
页码:412 / 419
页数:8
相关论文
共 19 条
[1]  
*AM NAT STAND I, 2000, 1361 ANSI Z
[2]  
BAJRASZEWSKI T, 2004, IN PRESS P SPIE, V5316
[3]  
*C ZEISS MED INC, 2003, STRATUSOCT MOD 300 U, P1
[4]  
*C ZEISS MED INC, 2003, STRATUSOCT MOD 300 U, P7
[5]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[6]   Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Sattmarin, H ;
Hermann, B ;
Ko, TH ;
Stur, M ;
Unterhuber, A ;
Scholda, C ;
Findl, O ;
Wirtitsch, M ;
Fujimoto, JG ;
Fercher, AF .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (05) :695-706
[7]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507
[8]  
GARTNER LP, 1994, COLOR ATLAS HISTOLOG, V19, P2
[9]   Histologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography [J].
Gloesmann, M ;
Hermann, B ;
Schubert, C ;
Sattmann, H ;
Ahnelt, PK ;
Drexler, W .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (04) :1696-1703
[10]   Three-dimensional imaging of the human retina by high-speed optical coherence tomography [J].
Hitzenberger, CK ;
Trost, P ;
Lo, PW ;
Zhou, QY .
OPTICS EXPRESS, 2003, 11 (21) :2753-2761