Vascularity of hepatocellular carcinoma: Assessment with contrast-enhanced second-harmonic versus conventional power Doppler US

被引:91
作者
Choi, BI
Kim, TK
Han, JK
Kim, AY
Seong, CK
Park, SJ
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
[2] Seoul Natl Univ Hosp, Inst Radiat Med, Chongno Gu, Seoul 110744, South Korea
关键词
liver neoplasms; blood supply; US; ultrasound; (US); artifact; comparative studies; contrast media; harmonic study; power Doppler;
D O I
10.1148/radiology.214.2.r00fe01381
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare contrast material-enhanced harmonic power Doppler ultrasonography (US) with conventional power Doppler US in depicting the vascularity of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty patients with nodular HCCs (2.6-13.2 cm in diameter; mean diameter, 4.8 cm) were prospectively examined with both conventional and harmonic power Doppler US. US was performed with a 2-4-MHz curved linear-array transducer according to a standard examination protocol (1,000-Hz pulse repetition frequency, medium wall filter, and power gain of 55%-84% for conventional power Doppler US; 700-Hz pulse repetition frequency, low wall filter, and power gain of 95%-98% for harmonic power Doppler US). Serial, dynamic scans were obtained before intravenous injection of the contrast agent (SH U 508A) and at 30, 60, 90, 120, 180, 240, and 300 seconds after injection with both techniques. RESULTS: The number of intratumoral power Doppler US signals was similar with both techniques at 30-90 seconds after contrast agent injection; however, after 90 seconds, conventional power Doppler US depicted significantly more signals than did harmonic power Doppler US. Harmonic power Doppler US was superior to conventional power Doppler US in terms of power Doppler artifacts such as "blooming" or motion-related artifacts. CONCLUSION: Although the effective enhancement duration is relatively short compared with that for conventional power Doppler US, contrast-enhanced harmonic power Doppler US can be effective in evaluating the vascularity of HCCs because of the advantage of fewer power Doppler artifacts.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 20 条
[1]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[2]   Power versus conventional color Doppler sonography: Comparison in the depiction of vasculature in liver tumors [J].
Choi, BI ;
Kim, TK ;
Han, JK ;
Chung, JW ;
Park, JH ;
Han, MC .
RADIOLOGY, 1996, 200 (01) :55-58
[3]  
ders F, 1994, ULTRASOUND MED BIOL, V20, P137, DOI [10.1016/0301-5629(94)90078-7, DOI 10.1016/0301-5629(94)90078-7]
[4]  
FORSBERG F, 1994, J ULTRAS MED, V13, P357
[5]   COLOR DOPPLER SONOGRAPHY OF HEPATIC-TUMORS WITH A GALACTOSE-BASED CONTRAST AGENT - CORRELATION WITH ANGIOGRAPHIC FINDINGS [J].
FUJIMOTO, M ;
MORIYASU, F ;
NISHIKAWA, K ;
NADA, T ;
OKUMA, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1099-1104
[6]  
Goldberg BB, 1996, J ULTRAS MED, V15, P127
[7]  
Hosoki T, 1997, ACTA RADIOL, V38, P422
[8]   Hepatocellular carcinoma: Power Doppler US with a contrast agent - Preliminary results [J].
Kim, AY ;
Choi, BI ;
Kim, TK ;
Han, JK ;
Yun, EJ ;
Lee, KY ;
Han, MC .
RADIOLOGY, 1998, 209 (01) :135-140
[9]   Gray-scale second harmonic imaging of the liver with galactose-based microbubbles [J].
Kono, Y ;
Moriyasu, F ;
Mine, Y ;
Nada, T ;
Kamiyama, N ;
Suginoshita, Y ;
Matsumura, T ;
Kobayashi, K ;
Chiba, T .
INVESTIGATIVE RADIOLOGY, 1997, 32 (02) :120-125
[10]  
Leen E, 1996, CLIN RADIOL, V51, P35