Rapid right ventricular pacing is an alternative to adenosine in catheter interventional procedures for congenital heart disease

被引:51
作者
Daehnert, I [1 ]
Rotzsch, C [1 ]
Wiener, M [1 ]
Schneider, P [1 ]
机构
[1] Univ Leipzig, Klin Kinderkardiol, Herzzentrum, D-04289 Leipzig, Germany
关键词
D O I
10.1136/hrt.2003.025650
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To describe the use of rapid right ventricular pacing to facilitate balloon stability during balloon dilatation procedures for congenital heart disease. Setting: Tertiary paediatric cardiac centre. Design and patients: This was a prospective pilot study of 37 consecutive patients with congenital aortic stenosis undergoing elective balloon dilatation. If the first dilatation manoeuvre failed due to balloon displacement, rapid right ventricular pacing at a rate of 220 beats/min was performed during repeat balloon inflation. Interventions: Balloon aortic valvotomy and rapid right ventricular pacing. Main outcome measures: Balloon stability versus displacement during balloon dilatation and procedure related complications. Results: Initial balloon displacement occurred and rapid right ventricular pacing was performed in 14 patients. The balloon remained in stable position in 11 patients. In three patients the balloon was displaced. In two of them an increase of the pacing rate to 240 beats/min provided balloon stability. In one patient stability was obtained at an unchanged pacing rate after correction of a suboptimal balloon position. No sustained arrhythmias occurred. There were no other procedure related complications. Conclusions: Rapid right ventricular pacing is a safe and effective method to provide balloon stability during balloon dilatation of the aortic valve. It may be applied in other fields of catheter intervention where it is desirable to maintain stable device positions during the critical phase of the procedure.
引用
收藏
页码:1047 / 1050
页数:4
相关论文
共 14 条
  • [1] Outcomes of uncomplicated aortic valve stenosis presenting in infants
    Baram, S
    McCrindle, BW
    Han, RK
    Benson, LN
    Freedom, RM
    Nykanen, DG
    [J]. AMERICAN HEART JOURNAL, 2003, 145 (06) : 1063 - 1070
  • [2] Balloon occlusion delivery technique for closure of patent ductus arteriosus
    Berdjis, F
    Moore, JW
    [J]. AMERICAN HEART JOURNAL, 1997, 133 (05) : 601 - 604
  • [3] Borghi A, 1999, Heart, V82, pe10
  • [4] Stenting of coarctation of the aorta
    Cheatham, JP
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) : 112 - 125
  • [5] Adenosine induced transient cardiac standstill in catheter interventional procedures for congenital heart disease
    De Giovanni, JV
    Edgar, RA
    Cranston, A
    [J]. HEART, 1998, 80 (04) : 330 - 333
  • [6] Dorros G, 1996, J ENDOVASC SURG, V3, P270, DOI 10.1583/1074-6218(1996)003<0270:AITCAE>2.0.CO
  • [7] 2
  • [8] Adenosine-induced ventricular asystole to induce transient profound systemic hypotension in patients undergoing endovascular therapy - Dose-response characteristics
    Hashimoto, T
    Young, WL
    Aagaard, BD
    Joshi, S
    Ostapkovich, ND
    Pile-Spellman, J
    [J]. ANESTHESIOLOGY, 2000, 93 (04) : 998 - 1001
  • [9] ING FF, 2001, PROG PEDIATR CARDIOL, V14, P13
  • [10] Kahn RA, 2000, J ENDOVASC THER, V7, P292, DOI 10.1583/1545-1550(2000)007<0292:SAEOHD>2.3.CO