Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP, and measurements

被引:66
作者
Chibani, O [1 ]
Li, XA [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
D O I
10.1118/1.1473134
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric dose measurements for 0.5 and 1 MeV electron beams incident on homogeneous and multilayer media are compared with the predictions of the three codes. Comparison with dose measurements in two-layer media exposed to a Co-60 gamma source is also pet-formed. In addition, comparisons between the codes (including the EGS4 code) are done for (a) 0.05 to 10 MeV electron beams and positron point sources in lead, (b) high-energy photons (10 and 20 MeV) irradiating a multilayer phantom (water/steel/air), and (c) simulation of a Sr-90/Y-90 brachytherapy source. A good agreement is observed between the calorimetric electron dose measurements and predictions of GEPTS and EGSnrc in both homogeneous and multilayer media. MCNP outputs are found to be dependent on the energy-indexing method (Default/ITS style). This dependence is significant in homogeneous media as well as at interfaces. MCNPITS fits more closely the experimental data than MCNPDEF, except for the case of Be. At low energy (0.05 and 0.1 MeV), MCNPITS dose distributions in lead show higher maximums in comparison with GEPTS and EGSnrc. EGS4 produces too penetrating electron-dose distributions in high-Z media, especially at low energy (<0.1 MeV). For positrons, differences between GEPTS and EGSnrc are observed in lead because GEPTS distinguishes positrons from electrons for both elastic multiple scattering and bremsstrahlung emission models. For the Co-60 source, a quite good agreement between calculations and measurements is observed with regards to the experimental uncertainty. For the other cases (10 and 20 MeV photon sources and the Sr-90/Y-90 beta source), a good agreement is found between the three codes. In conclusion, differences between GEPTS and EGSnrc results are found to be very small for almost all media and energies studied. MCNP results depend significantly on the electron energy-indexing method. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:835 / 847
页数:13
相关论文
共 60 条
[1]  
[Anonymous], 1988, MONTE CARLO TRANSPOR, DOI DOI 10.1007/978-1-4613-1059-4_2
[2]  
Berger M.J., 1963, METHODS COMPUT PHYS, P135
[3]  
BERGER MJ, 1985, ETRAN MONTE CARLO CO
[4]  
BERGERMJ, 1996, DLC174 ORNL
[6]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[7]   ZUM ENERGIEVERLUST SCHNELLER ELEKTRONEN IN DUNNEN SCHICHTEN [J].
BLUNCK, O ;
LEISEGANG, S .
ZEITSCHRIFT FUR PHYSIK, 1950, 128 (04) :500-505
[8]  
Briesmeister J.F., 2000, LA13709M LOS AL NAT
[9]   New algorithms for the Vavilov distribution calculation and the corresponding energy loss sampling [J].
Chibani, O .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (05) :2288-2292
[10]   ELECTRON DEPTH-DOSE DISTRIBUTIONS IN WATER, IRON AND LEAD - THE GEPTS SYSTEM [J].
CHIBANI, O .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 101 (04) :357-378