New limited sampling strategy for determining 5-fluorouracil area under the concentration-time curve after rapid intravenous bolus

被引:14
作者
Gusella, M
Ferrazzi, E
Ferrari, M
Padrini, R
机构
[1] Univ Padua, Dept Pharmacol & Anesthesiol, I-35131 Padua, Italy
[2] Univ Padua, Dept Clin & Expt Med, I-35131 Padua, Italy
[3] Rovigo Hosp, Div Oncol, Rovigo, Italy
关键词
5-fluorouracil; limited sampling method; area under the curve; pharmacokinetics;
D O I
10.1097/00007691-200206000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
All limited sampling models so far proposed to determine the area under the concentration-time curve (AUC) of anticancer drugs can be applied only to the dosing/sampling schedule used to obtain the model. The authors have developed a new method to predict the AUC of 5-fluorouracil (5-FU) after rapid intravenous bolus administration of various doses, using as few as two plasma drug concentrations. The 5-FU AUC (AUC(true)) was First determined in 20 patients receiving adjuvant therapy for colorectal cancer, based on nine plasma drug concentrations obtained at 0, 2.5, 5, 10, 15, 20, 30, 45, and 60 minutes after drug administration. Ten patients received 375 mg/m(2) 5F-U + 100 mg/m(2) leucovorin and 10 received 425 mg/m(2) 5-FU + 20 mg/m(2) leucovorin. The kinetics of 5-FU was described by either a one- or two-compartment linear model, as needed. The AUC was then recalculated (AUC(approx)) using a reduced number of plasma concentrations and a simple one-compartment model. The time combinations tested Were 2.5, 5, 10, and 20; 2.5, 10, and 20; 5, 10, and 20; 5 and 20; and 2,5 and 20 minutes. The accuracy and precision of the method in predicting the AUC(true) were measured by calculating the mean prediction error (MPE%) and the mean absolute error (MAE%) of the AUC(approx). MPE% ranged between -0.8% and -8.3% and MAE% between 6.1% and 9.5%, depending on the time combination used. In general, all limited sampling models tested tended to underestimate the AUC(true) slightly, particularly when 5-FU kinetics followed a two-compartment model, but bias was still within acceptable limits. The best results were obtained with plasma concentrations measured at 2.5 and 20 minutes after drug bolus (MPE%, -0.8%; MAE%, 6.1%). Although 5-FU kinetics was dose-dependent, MPE% and MAE% were not significantly different between the two groups. These data show that 5-FU AUC can be reliably predicted by using just two plasma concentrations and a one-compartment model, even when different doses are used and plasma concentration decay is biexponential.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 18 条
[1]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[2]  
Bocci G, 2000, CLIN CANCER RES, V6, P3032
[3]   A SENSITIVE METHOD FOR DETERMINATION OF 5-FLUOROURACIL AND 5-FLUORO-2'-DEOXYURIDINE IN HUMAN-PLASMA BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
BUCKPITT, AR ;
BOYD, MR .
ANALYTICAL BIOCHEMISTRY, 1980, 106 (02) :432-437
[4]   Practical treatment guide for dose individualisation in cancer chemotherapy [J].
Canal, P ;
Chatelut, E ;
Guichard, S .
DRUGS, 1998, 56 (06) :1019-1038
[5]  
CHRISTOPHIDIS N, 1979, CLIN CHEM, V25, P83
[6]  
Dollery C., 1999, THERAPEUTIC DRUGS, pF103
[7]   Long-term weekly treatment of colorectal metastatic cancer with fluorouracil and leucovorin:: Results of a multicentric prospective trial of fluorouracil dosage optimization by pharmacokinetic monitoring in 152 patients [J].
Gamelin, É ;
Boisdron-Celle, M ;
Delva, R ;
Regimbeau, C ;
Cailleux, PE ;
Alleaume, C ;
Maillet, ML ;
Goudier, MJ ;
Sire, M ;
Person-Joly, MC ;
Maigre, M ;
Maillart, P ;
Fety, R ;
Burtin, P ;
Lortholary, A ;
Dumesnil, Y ;
Picon, L ;
Geslin, J ;
Gesta, P ;
Danquechin-Dorval, E ;
Larra, F ;
Robert, J .
JOURNAL OF CLINICAL ONCOLOGY, 1998, 16 (04) :1470-1478
[8]   PHARMACOKINETIC OPTIMIZATION OF ANTICANCER THERAPY [J].
LILIEMARK, J ;
PETERSON, C .
CLINICAL PHARMACOKINETICS, 1991, 21 (03) :213-231
[9]   TREATMENT OF ADVANCED COLORECTAL AND GASTRIC ADENOCARCINOMAS WITH 5-FLUOROURACIL AND HIGH-DOSE FOLINIC ACID [J].
MACHOVER, D ;
GOLDSCHMIDT, E ;
CHOLLET, P ;
METZGER, G ;
ZITTOUN, J ;
MARQUET, J ;
VANDENBULCKE, JM ;
MISSET, JL ;
SCHWARZENBERG, L ;
FOURTILLAN, JB ;
GAGET, H ;
MATHE, G .
JOURNAL OF CLINICAL ONCOLOGY, 1986, 4 (05) :685-696
[10]   A comparative computer simulation study of three different sparse-sampling methods for the estimation of steady-state area under the concentration-time curve (AUC) and maximum concentration (C-max) in toxicokinetics [J].
Mahmood, I .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1997, 86 (05) :579-583