Transdermal delivery of insulin using microneedles in vivo

被引:481
作者
Martanto, W
Davis, SP
Holiday, NR
Wang, J
Gill, HS
Prausnitz, MR [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
diabetes; microelectromechanical systems (MEMS); microfabrication; skin; transdermal drug delivery;
D O I
10.1023/B:PHAM.0000029282.44140.2e
中图分类号
O6 [化学];
学科分类号
0703 [化学];
摘要
Purpose. The purpose of this study was to design and fabricate arrays of solid microneedles and insert them into the skin of diabetic hairless rats for transdermal delivery of insulin to lower blood glucose level. Methods. Arrays containing 105 microneedles were laser-cut from stainless steel metal sheets and inserted into the skin of anesthetized hairless rats with streptozotocin-induced diabetes. During and after microneedle treatment, an insulin solution (100 or 500 U/ml) was placed in contact with the skin for 4 h. Microneedles were removed 10 s, 10 min, or 4 h after initiating transdermal insulin delivery. Blood glucose levels were measured electrochemically every 30 min. Plasma insulin concentration was determined by radioimmunoassay at the end of most experiments. Results. Arrays of microneedles were fabricated and demonstrated to insert fully into hairless rat skin in vivo. Microneedles increased skin permeability to insulin, which rapidly and steadily reduced blood glucose levels to an extent similar to 0.05-0.5 U insulin injected subcutaneously. Plasma insulin concentrations were directly measured to be 0.5-7.4 ng/ml. Higher donor solution insulin concentration, shorter insertion time, and fewer repeated insertions resulted in larger drops in blood glucose level and larger plasma insulin concentrations. Conclusions. Solid metal microneedles are capable of increasing transdermal insulin delivery and lowering blood glucose levels by as much as 80% in diabetic hairless rats in vivo.
引用
收藏
页码:947 / 952
页数:6
相关论文
共 23 条
[1]
Scaling basic toxicokinetic parameters from rat to man [J].
Bachmann, K ;
Pardoe, D ;
White, D .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1996, 104 (04) :400-407
[2]
BANCROFT JD, 2002, FTHEORY PRACTICE HIS
[3]
BERNER B, 1998, ELECT CONTROLLED DRU
[4]
Bronaugh R, 1999, Percutaneous absorption : drugs-cosmetics-mechanisms-methodology
[5]
DAVIS SP, IN PRESS J BIOMECH
[6]
Graham A. K., 1971, ELECTROPLATING ENG H
[7]
Microfabricated microneedles: A novel approach to transdermal drug delivery [J].
Henry, S ;
McAllister, DV ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (08) :922-925
[8]
Hensel K.B., 2000, ELECTROPOLISHING MET, V98, P440, DOI DOI 10.1016/S0026-0576(00)80353-0
[9]
JAROSZESKI MJ, 1999, ELECTROCHEMOTHERAPY
[10]
Lack of pain associated with microfabricated microneedles [J].
Kaushik, S ;
Hord, AH ;
Denson, DD ;
McAllister, DV ;
Smitra, S ;
Allen, MG ;
Prausnitz, MR .
ANESTHESIA AND ANALGESIA, 2001, 92 (02) :502-504