Differentiation of recurrent rectal cancer and scarring with dynamic MR imaging

被引:39
作者
Dicle, O [1 ]
Obuz, F [1 ]
Çakmakci, H [1 ]
机构
[1] Dokuz Eylul Univ, Fac Med, Dept Radiodiag, TR-0090232 Izmir, Turkey
关键词
D O I
10.1259/bjr.72.864.10703471
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy of dynamic contrast enhanced magnetic resonance (MR) imaging in the differentiation of malignant and benign pelvic lesions during follow-up of patients with treated colorectal tumours was evaluated prospectively. 19 patients (11 men, 8 women; age range 35-70 years; mean 57 years) with suspected local recurrence of colorectal malignancy were evaluated with MR imaging. Dynamic MR imaging with axial Turbo-FLASH gradient echo imaging and bolus injection of contrast medium was performed. Dynamic images, each consisting of one slice in the same location, were acquired at 5, 10, 15, 20 and 30 s, and at 1, 2, 3, 4, 5 and 10 min. The maximum change in signal intensity (E-max), the acceleration rate of the time-intensity curve (TIC) and the ratio of the signal intensity of the lesions to the signal intensity of the iliac artery (SIL/SIA) were used as the enhancement parameters. The TIC and SIL/SIA ratio at 60 s were found to be valuable in the differential diagnosis; E-max had no significance in differentiating benign and malignant lesions. Sensitivity was 83% for each calculated parameter. SIL/SIA has the highest specificity and accuracy among the parameters.
引用
收藏
页码:1155 / 1159
页数:5
相关论文
共 13 条
[1]   Breast lesions: Correlation of contrast medium enhancement patterns on MR images with histopathologic findings and tumor angiogenesis [J].
Buadu, LD ;
Murakami, J ;
Murayama, S ;
Hashiguchi, N ;
Sakai, S ;
Masuda, K ;
Toyoshima, S ;
Kuroki, S ;
Ohno, S .
RADIOLOGY, 1996, 200 (03) :639-649
[2]   SUSPECTED RECURRENT RECTOSIGMOID CARCINOMA AFTER ABDOMINO-PERINEAL RESECTION - MR IMAGING AND HISTOPATHOLOGIC FINDINGS [J].
DELANGE, EE ;
FECHNER, RE ;
WANEBO, HJ .
RADIOLOGY, 1989, 170 (02) :323-328
[3]   TUMOR RECURRENCE VERSUS FIBROSIS IN THE FEMALE PELVIS - DIFFERENTIATION WITH MR IMAGING AT 1.5-T [J].
EBNER, F ;
KRESSEL, HY ;
MINTZ, MC ;
CARLSON, JA ;
COHEN, EK ;
SCHIEBLER, M ;
GEFTER, W ;
AXEL, L .
RADIOLOGY, 1988, 166 (02) :333-340
[4]  
EBNER F, 1988, RADIOLOGY, V168, P286
[5]  
Gualdi G F, 1990, Radiol Med, V79, P479
[6]   MR IMAGING OF THE BREAST WITH GD-DTPA - USE AND LIMITATIONS [J].
HEYWANG, SH ;
WOLF, A ;
PRUSS, E ;
HILBERTZ, T ;
EIERMANN, W ;
PERMANETTER, W .
RADIOLOGY, 1989, 171 (01) :95-103
[7]   Dynamic contrast-enhanced subtraction versus T2-weighted spin-echo MR imaging in the follow-up of colorectal neoplasm: A prospective study of 41 patients [J].
Kinkel, K ;
Tardivon, AA ;
Soyer, P ;
Spatz, A ;
Lasser, P ;
Rougier, P ;
Vanel, D .
RADIOLOGY, 1996, 200 (02) :453-458
[8]  
RICH T, 1983, CANCER-AM CANCER SOC, V52, P1317, DOI 10.1002/1097-0142(19831001)52:7<1317::AID-CNCR2820520731>3.0.CO
[9]  
2-6
[10]  
SCHIMPFLE MM, 1993, RADIOLOGY, V189, P881