A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays

被引:105
作者
Mueller, JL [1 ]
Isaacson, D
Newell, JC
机构
[1] Rensselaer Polytech Inst, Dept Math Sci, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
基金
美国国家科学基金会;
关键词
electrical impedance tomography (EIT); reconstruction algorithm; rectangular electrode array;
D O I
10.1109/10.797998
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A three-dimensional reconstruction algorithm in electrical impedance imaging is presented for determining the conductivity distribution beneath the surface of a medium, given surface voltage data measured on a rectangular array of electrodes. Such an electrode configuration may be desirable for using electrical impedence tomography to detect tumors in the human breast. The algorithm is based on linearizing the conductivity about a constant value. Here, me describe a simple implementation of the algorithm on a four-electrode-by-four-electrode array and the reconstructions obtained from numerical and experimental tank data. The results demonstrate significantly better spatial resolution in the plane of the electrodes than with respect to depth.
引用
收藏
页码:1379 / 1386
页数:8
相关论文
共 27 条
  • [1] [Anonymous], 1998, J ENVIRON ENG GEOPH
  • [2] Blue R. S., 1997, Real-time three-dimensional electrical impedance tomography
  • [3] Brebbia CA., 1984, BOUNDARY ELEMENT TEC, DOI DOI 10.1007/978-3-642-48860-3
  • [4] CALDERON AP, 1980, SOC BRASILEIRA MATEM, V2, P65
  • [5] Electrical impedance tomography
    Cheney, M
    Isaacson, D
    Newell, JC
    [J]. SIAM REVIEW, 1999, 41 (01) : 85 - 101
  • [6] Cheney M, 1990, Int J Imaging Syst Technol, V2, P66, DOI 10.1002/ima.1850020203
  • [7] ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY
    CHENG, KS
    ISAACSON, D
    NEWELL, JC
    GISSER, DG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) : 918 - 924
  • [8] ACT3 - A HIGH-SPEED, HIGH-PRECISION ELECTRICAL-IMPEDANCE TOMOGRAPH
    COOK, RD
    SAULNIER, GJ
    GISSER, DG
    GOBLE, JC
    NEWELL, JC
    ISAACSON, D
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (08) : 713 - 722
  • [9] A REAL-TIME ELECTRICAL-IMPEDANCE TOMOGRAPH
    EDIC, PM
    SAULNIER, GJ
    NEWELL, JC
    ISAACSON, D
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (09) : 849 - 859
  • [10] ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY AND EIGENVALUES
    GISSER, DG
    ISAACSON, D
    NEWELL, JC
    [J]. SIAM JOURNAL ON APPLIED MATHEMATICS, 1990, 50 (06) : 1623 - 1634