Problems and uncertainties with multiple point A's during multiple high-dose-rate intracavitary brachytherapy in carcinoma of the cervix

被引:9
作者
Datta, NR
Basu, R
Das, KJM
Rajasekar, D
Pandey, CM
Singh, U
Ayyagari, S
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Dept Radiotherapy, Lucknow 226014, Uttar Pradesh, India
[2] Sanjay Gandhi Postgrad Inst Med Sci, Dept Biostat, Lucknow 226014, Uttar Pradesh, India
关键词
cancer cervix; intracavitary brachytherapy; point A dose prescription; high dose rate;
D O I
10.1016/j.clon.2003.10.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: This study evaluates the consequences of point A as a dose prescription point during multiple high-dose-rate (HDR) intracavitary brachytherapy (ICBT) in cancer cervix. Materials and methods: Fifty patients who had received teletherapy were randomised into two groups of 25 to receive three HDR ICBT fractions of 6 Gy each at point A with either a flexible Ralstron (Shimadzu Corporation, Japan) or rigid Rotterdam (Nucletron, Netherlands) applicator. The orthogonal radiographs of the 150 applications were evaluated for applicator geometry and point A co-ordinates. Results: Irrespective of the nature and rigidity of the applicators, its various components exhibited a highly significant variation during multiple fractionated HDR ICBT. The Cartesian co-ordinates of point A (left and right) for the applicator geometry also showed significant variation during multiple HDR ICBT procedures. This resulted in an average shift of 9.5 mm (SD= +/-4.4) and 11.1 mm (SD= +/-6.4) in right point A, 10.2 mm (SD= +/-4.5) and 10.8 min (SD= +/-6.6) in left point A for Ralstron and Rotterdam applicator, respectively, during the three HDR ICBT. Consequently, doses to both right and left point A's showed significant variation during multiple ICBT application and were independent of the applicator type. Conclusion: Applicator variation in the components and spatial position in the pelvis during multiple HDR ICBT results in multiple point A's irrespective of the nature of applicator, leading to uncertainty in the dose prescription. These uncertainties, which have a bearing on clinical end points, could be minimised by shifting from point-based dose prescription to image-based target localisation and treatment planning in ICBT. (C) 2004 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 1985, 38 ICRU
[2]  
Bahena JH, 1998, INT J RADIAT ONCOL, V41, P13
[3]  
DAS KR, 1987, ENDOCURIE HYPERTHERM, V3, P81
[4]   Variations of intracavitary applicator geometry during multiple HDR brachytherapy insertions in carcinoma cervix and its influence on reporting as per ICRU report 38 [J].
Datta, NR ;
Kumar, S ;
Das, KJM ;
Pandey, CM ;
Halder, S ;
Ayyagari, S .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :15-24
[5]  
ELHANAFY OA, 2002, J APPL CLIN MED PHYS, V2, P114
[6]   ANATOMIC VARIATION OF GYNECOLOGIC BRACHYTHERAPY PRESCRIPTION POINTS [J].
GRIGSBY, PW ;
GEORGIOU, A ;
WILLIAMSON, JF ;
PEREZ, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (03) :725-729
[7]   Changes in applicator position with fractionated high dose rate gynaecological brachytherapy [J].
Hoskin, PJ ;
Cook, M ;
Bouscale, D ;
Cansdale, J .
RADIOTHERAPY AND ONCOLOGY, 1996, 40 (01) :59-62
[8]   Quantification of intracavitary brachytherapy parameters and correlation with outcome in patients with carcinoma of the cervix [J].
Katz, A ;
Eifel, PJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1417-1425
[9]   MAJOR GEOMETRIC VARIATIONS BETWEEN MULTIPLE HIGH-DOSE-RATE APPLICATIONS OF BRACHYTHERAPY IN CANCER OF THE CERVIX - FREQUENCY AND TYPES OF VARIATION [J].
KIM, RY ;
MEYER, JT ;
PLOTT, WE ;
SPENCER, SA ;
MEREDITH, RF ;
JENNELLE, RLS ;
SALTER, MM .
RADIOLOGY, 1995, 195 (02) :419-422
[10]  
King G C, 2000, Med Dosim, V25, P77, DOI 10.1016/S0958-3947(00)00032-7