Developing a quality control protocol for diffusion imaging on a clinical MRI system

被引:54
作者
Delakis, I
Moore, EM
Leach, MO
De Wilde, JP
机构
[1] Univ London Imperial Coll Sci Technol & Med, Bagrit Ctr, Dept Bioengn, MagNET, London SW7 2AZ, England
[2] Inst Canc Res, Canc Res UK Clin MR Res Grp, Surrey, England
[3] Royal Marsden NHS Trust, Surrey, England
关键词
D O I
10.1088/0031-9155/49/8/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work describes the development of a quality control protocol, which can be implemented to assess the accuracy, precision and reproducibility of the apparent diffusion coefficient (ADC) measurement on a clinical magnetic resonance imaging (MRI) system. The precision and accuracy of the ADC measurement are analysed with regard to MRI system noise, signal reproducibility and differences between nominal and effective b values. Two aqueous test-solutions of CuSO4 and sucrose are prepared for the quality control protocol. ADC measurement with the CuSO4 Solution is more sensitive to differences between nominal and effective b values, on account of the solution's high ADC. ADC measurement with the sucrose solution is more sensitive to signal reproducibility due to the solution's low baseline signal intensity. The ADC of the test-solutions is measured on an MRI system at our centre with a sequence used for clinical studies using diffusion imaging. Two parameters, Q and R, are defined for the analysis of the quality control ADC values. The Q parameter is the ratio of the standard deviation of the quality control mean ADC values over time to the optimal standard deviation, as derived from the effect of thermal noise on the ADC measurement uncertainty. Analysis with the Q parameter indicates that signal reproducibility errors contribute to ADC variations on our MRI system when imaging with high b values (b > 500 mm s(-2)), whereas differences between nominal and effective b values have a greater impact on the ADC measurement when imaging with low b values (b < 500 mm s(-2)). The R parameter is defined as the ratio of the directional variation of the ADC quality control values to the uncertainty of the ADC measurement. Analysis with the R parameter shows that the effect of directional variation of the ADC measurement on our MRI system is more pronounced when imaging with low b values. The quality control protocol identified a systematic error, which introduced a small system-induced anisotropy in the ADC measurement. This error is currently taken into account in the analysis of clinical studies employing the diffusion imaging sequence used in this quality control protocol.
引用
收藏
页码:1409 / 1422
页数:14
相关论文
共 18 条
  • [1] ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03): : 247 - 254
  • [2] DELAKIS I, 2002, P EUR SOC MAGN RES M
  • [3] T2-based segmentation of periventricular volumes for quantification of proton magnetic resonance spectra of multiple sclerosis lesions
    Helms, G
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2003, 16 (01) : 10 - 16
  • [4] Apparent Diffusion Coefficient: a quantitative parameter for in vivo tumor characterization
    Herneth, AM
    Guccione, S
    Bednarski, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (03) : 208 - 213
  • [5] A phantom for diffusion-weighted imaging of acute stroke
    Laubach, HJ
    Jakob, PM
    Loevblad, KO
    Baird, AE
    Bovo, MP
    Edelman, RR
    Warach, S
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06) : 1349 - 1354
  • [6] TEMPERATURE MAPPING WITH MR IMAGING OF MOLECULAR-DIFFUSION - APPLICATION TO HYPERTHERMIA
    LEBIHAN, D
    DELANNOY, J
    LEVIN, RL
    [J]. RADIOLOGY, 1989, 171 (03) : 853 - 857
  • [7] LERSKI R, 1998, QUALITY CONTROL MAGN
  • [8] SELF-DIFFUSION IN NORMAL AND HEAVY-WATER IN RANGE 1-45 DEGREES
    MILLS, R
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1973, 77 (05) : 685 - 688
  • [9] Brain gray and white matter transverse relaxation time in schizophrenia
    Pfefferbaum, A
    Sullivan, EV
    Hedehus, M
    Moseley, M
    Lim, KO
    [J]. PSYCHIATRY RESEARCH-NEUROIMAGING, 1999, 91 (02) : 93 - 100
  • [10] Diffusion tensor MR imaging of the human brain
    Pierpaoli, C
    Jezzard, P
    Basser, PJ
    Barnett, A
    DiChiro, G
    [J]. RADIOLOGY, 1996, 201 (03) : 637 - 648