A high-throughput urinalysis of abused drugs based on a SPE-LC-MS/MS method coupled with an in-house developed post-analysis data treatment system

被引:33
作者
Cheng, Wing-Chi [1 ]
Yau, Tsan-Sang [1 ]
Wong, Ming-Kei [1 ]
Chan, Lai-Ping [1 ]
Mok, Vincent King-Kuen [1 ]
机构
[1] Homantin Govt Off, Forens Sci Div, Govt Lab, Homantin, Hong Kong, Peoples R China
关键词
urinalysis; LC-MS; drugs of abuse; data management system; CHROMATOGRAPHY-MASS-SPECTROMETRY; URINE; KETAMINE;
D O I
10.1016/j.forsciint.2006.04.019
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A rapid urinalysis system based on SPE-LC-MSIMS with an in-house post-analysis data management system has been developed for the simultaneous identification and semi-quantitation of opiates (morphine, codeine), methadone, amphetamines (amphetamine, methylamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)), 11-benzodiazepines or their metabolites and ketamine. The brine samples are subjected to automated solid phase extraction prior to analysis by LC-MS (Finnigan Surveyor LC connected. to a Finnigan LCQ Advantage) fitted with an Alltech Rocket Platinum EPS C-18 column. With a single point calibration at the cut-off concentration for each analyte, simultaneous identification and semi-quantitation for the above mentioned drugs can be achieved in a 10 min run per urine sample. A computer macro-program package was developed to automatically retrieve appropriate data from the analytical data files, compare results with preset values (such as cut-off concentrations, MS matching scores) of each drug being analyzed and generate user-defined Excel reports to indicate all positive and negative results in batch-wise manner for ease of checking. The final analytical results are automatically copied into an Access database for report generation purposes. Through the use of automation in sample preparation, simultaneous identification and semi-quantitation by LC-MS/MS and a tailored made post-analysis data management system, this new urinalysis system significantly improves the quality of results, reduces the post-data treatment time, error due to data transfer and is suitable for high-throughput laboratory in batch-wise operation. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:95 / 107
页数:13
相关论文
共 15 条
[1]   Rapid determination of ketamine in urine by liquid chromatography-tandem mass spectrometry for a high throughput laboratory [J].
Cheng, JYK ;
Mok, VKK .
FORENSIC SCIENCE INTERNATIONAL, 2004, 142 (01) :9-15
[2]   Urine drug testing for opioids, cocaine, and metabolites by direct injection liquid chromatography/tandem mass spectrometry [J].
Dams, R ;
Murphy, CM ;
Lambert, WE ;
Huestis, MA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (14) :1665-1670
[3]  
ESKBRIDGE SD, 1997, PHARMACOTHERAPY, V17, P497
[4]  
Fitzgerald RL, 1999, CLIN CHEM, V45, P1224
[5]   Position of immunological techniques in screening in clinical toxicology [J].
George, S .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (11) :1288-1309
[6]  
Jemal M, 2000, BIOMED CHROMATOGR, V14, P422, DOI 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO
[7]  
2-I
[8]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[9]   Advances in analytical toxicology: the current role of liquid chromatography-mass spectrometry in drug quantification in blood and oral fluid [J].
Maurer, HH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) :110-118
[10]   Liquid chromatography mass spectrometry in forensic and clinical toxicology [J].
Maurer, HH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (01) :3-25