Determination of ribavirin in human serum and plasma by capillary electrophoresis

被引:41
作者
Breadmore, MC [1 ]
Theurillat, R [1 ]
Thormann, W [1 ]
机构
[1] Univ Bern, Dept Clin Pharmacol, CH-3010 Bern, Switzerland
关键词
capillary electrophoresis; high-performance liquid chromatography; ribavirin; therapeutic drug monitoring;
D O I
10.1002/elps.200305819
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The electrophoretic separation of ribavirin and 5-methylcytidine (internal standard) by capillary electrophoresis was examined. Separation was achieved using reverse polarity in a 100 mm borate electrolyte, pH 9.1, with 5 mm spermine added to reduce the electroosmotic flow. Sample preparation based on acetonitrile protein precipitation was found to be unsuitable for ribavirin analysis in patient samples due to insufficient sensitivity and interferences. Solid-phase extraction employing phenyl boronic acid cartridges provided cleaner separations. Using this approach with 500 muL sample and reconstitution of the dried extract into 100 muL of 33% v/v 100 mM phosphate buffer, pH 6.4 / 67% v/v acetonitrile, the detection and quantitation limits were determined to be 0.05 and 0.10 mug/mL, respectively, a sensitivity that is suitable for therapeutic drug monitoring of ribavirin in human plasma and serum samples. The method was validated and compared to a high-performance liquid chromatography (HPLC) method, showing excellent agreement between the two for a set of samples that stemmed from patients being treated with ribavirin and interferon-alpha-2b for a hepatitis C virus infection.
引用
收藏
页码:1615 / 1622
页数:8
相关论文
共 19 条
[1]  
Glue P, 1999, SEMIN LIVER DIS, V19, P17
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) ASSAY FOR RIBAVIRIN AND COMPARISON OF THE HPLC ASSAY WITH RADIOIMMUNOASSAY [J].
GRANICH, GG ;
KROGSTAD, DJ ;
CONNOR, JD ;
DESROCHERS, KL ;
SHERWOOD, C .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1989, 33 (03) :311-315
[3]   High-performance liquid chromatographic determination of ribavirin in whole blood to assess disposition in erythrocytes [J].
Homma, M ;
Jayewardene, AL ;
Gambertoglio, J ;
Aweeka, F .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1999, 43 (11) :2716-2719
[4]   Increased mitochondrial toxicity with ribavirin in HIV/HCV coinfection [J].
Lafeuillade, A ;
Hittinger, G ;
Chadapaud, S .
LANCET, 2001, 357 (9252) :280-281
[5]   SEPARATION OF BORON-COMPLEXED DIOL COMPOUNDS USING HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
LANDERS, JP ;
ODA, RP ;
SCHUCHARD, MD .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2846-2851
[6]   Ribavirin quantification in combination treatment of chronic hepatitis C [J].
Larrat, S ;
Stanke-Labesque, F ;
Plages, A ;
Zarski, JP ;
Bessard, G ;
Souvignet, C .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2003, 47 (01) :124-129
[7]   RIBAVIRIN DISPOSITION IN HIGH-RISK PATIENTS FOR ACQUIRED-IMMUNODEFICIENCY-SYNDROME [J].
LASKIN, OL ;
LONGSTRETH, JA ;
HART, CC ;
SCAVUZZO, D ;
KALMAN, CM ;
CONNOR, JD ;
ROBERTS, RB .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1987, 41 (05) :546-555
[8]   PHARMACOKINETICS AND LONG-TERM TOLERANCE TO RIBAVIRIN IN ASYMPTOMATIC PATIENTS INFECTED WITH HUMAN-IMMUNODEFICIENCY-VIRUS [J].
LERTORA, JJL ;
REGE, AB ;
LACOUR, JT ;
FERENCZ, N ;
GEORGE, WJ ;
VANDYKE, RB ;
AGRAWAL, KC ;
HYSLOP, NE .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1991, 50 (04) :442-449
[9]   Specific, sensitive and accurate liquid chromatographic-tandem mass spectrometric method for the measurement of ribavirin in rat and monkey plasma [J].
Lin, CC ;
Yeh, LT ;
Lau, JY .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02) :241-248
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RIBAVIRIN IN SERUM AND URINE AND OF ITS URINARY METABOLITE 1,2,4-TRIAZOLE-3-CARBOXAMIDE [J].
PARONI, R ;
SIRTORI, CR ;
BORGHI, C ;
KIENLE, MG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 420 (01) :189-196