Parallel imaging reconstruction using automatic regularization

被引:213
作者
Lin, FH
Kwong, KK
Belliveau, JW
Wald, LL
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, MIT,Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, MIT, Div Hlth Sci & Technol, Charlestown, MA 02129 USA
[3] Massachusetts Gen Hosp, Dept Radiol, Charlestown, MA USA
关键词
D O I
10.1002/mrm.10718
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Increased spatiotemporal resolution in MRI can be achieved by the use of parallel acquisition strategies, which simultaneously sample reduced k-space data using the information from multiple receivers to reconstruct full-FOV images. The price for the increased spatiotemporal resolution in parallel MRI is the degradation of the signal-to-noise ratio (SNR) in the final reconstructed images. Part of the SNR reduction results when the spatially correlated nature of the information from the multiple receivers destabilizes the matrix inversion used in the reconstruction of the full-FOV image. In this work, a reconstruction algorithm based on Tikhonov regularization is presented that reduces the SNR loss due to geometric correlations in the spatial information from the array coil elements. Reference scans are utilized as a priori information about the final reconstructed image to provide regularized estimates for the reconstruction using the L-curve technique. This automatic regularization method reduces the average g-factors in phantom images from a two-channel array from 1.47 to 0.80 in twofold sensitivity encoding (SENSE) acceleration. In vivo anatomical images from an eight-channel system show an averaged g-factor reduction of 1.22 to 0.84 in 2.67-fold acceleration. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:559 / 567
页数:9
相关论文
共 20 条
[1]   Reduction of gradient acoustic noise in MRI using SENSE-EPI [J].
de Zwart, JA ;
van Gelderen, P ;
Kellman, P ;
Duyn, JH .
NEUROIMAGE, 2002, 16 (04) :1151-1155
[2]   Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging [J].
de Zwart, JA ;
Ledden, PJ ;
Kellman, P ;
van Gelderen, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1218-1227
[3]   GENERALIZED CROSS-VALIDATION AS A METHOD FOR CHOOSING A GOOD RIDGE PARAMETER [J].
GOLUB, GH ;
HEATH, M ;
WAHBA, G .
TECHNOMETRICS, 1979, 21 (02) :215-223
[4]  
Hansen P. C., 1998, RANK DEFICIENT DISCR
[5]  
KATSCHER U, 2002, P 10 ANN M ISMRM HON, P2396
[6]   Ghost artifact cancellation using phased array processing [J].
Kellman, P ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :335-343
[7]  
KING K, 1908, P 9 ANN M ISMRM GLAS, P1771
[8]  
LIANG ZP, 2002, P 10 ANN M ISMRM HON, P2388
[9]  
LIN FH, 2002, P INT SOC MAG RESON, P2389
[10]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO