Influence of natural temperature gradients on measurements of xylem sap flow with thermal dissipation probes. 1. Field observations and possible remedies

被引:108
作者
Do, F [1 ]
Rocheteau, A [1 ]
机构
[1] CNRS, CEFE, IRD, F-34293 Montpellier, France
关键词
Acacia tortilis; drylands; Granier probe; Sahelian zone;
D O I
10.1093/treephys/22.9.641
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
The thermal dissipation method is simple and widely used for measuring sap flow in large stems. As with several other thermal methods, natural temperature gradients are assumed to be negligible in the sapwood being measured. We studied the magnitude and variability of natural temperature gradients in sapwood of Acacia trees growing in the Sahelian zone of Senegal, analyzed their effects on sap flow measurements, and investigated possible solutions. A new measurement approach employing cyclic heating (45 minutes of heating and 15 minutes of cooling; 45/15) was also tested. Three-day measurement sequences that included 1 day without heating, a second day with continuous heating and a third day with cyclic heating were recorded during a 6.5-month period using probes installed at three azimuths in a tree trunk. Natural temperature gradients between the two probes of the sensor unit, spaced 8 to 10 cm vertically, were rarely negligible (i.e., < 0.2 degreesC): they were positive during the night and negative during the day, with an amplitude ranging from 0.3 to 3.5 degreesC depending on trunk azimuth, day and season. These temperature gradients had a direct influence on the signal from the continuously heated sensors, inducing fluctuations in the nighttime reference signal. The resulting errors in sap flow estimates can be greater than 100%. Correction protocols have been proposed in previous studies, but they were unsuitable because of the high spatial and temporal variability of the natural temperature gradients. We found that a measurement signal derived from a noncontinuous heating system could be an attractive solution because it appears to be independent of natural temperature gradients. The magnitude and variability of temperature gradients that we observed were likely exacerbated by the combination of open stand, high solar radiation and low sap flow rate. However, for all applications of the thermal dissipation method, it is wise to check regularly for natural temperature gradients by switching off the heater.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 19 条
[1]   MEASUREMENTS OF TRANSPIRATION FROM SAVANNA SHRUBS USING SAP FLOW GAUGES [J].
ALLEN, SJ ;
GRIME, VL .
AGRICULTURAL AND FOREST METEOROLOGY, 1995, 75 (1-3) :23-41
[2]   Regulation of water flux through trunks, branches, and leaves in trees of a lowland tropical forest [J].
Andrade, JL ;
Meinzer, FC ;
Goldstein, G ;
Holbrook, NM ;
Cavelier, J ;
Jackson, P ;
Silvera, K .
OECOLOGIA, 1998, 115 (04) :463-471
[3]   Sap flow measurements in grapevines (Vitis vinifera L.) -: 2.: Granier measurements [J].
Braun, P ;
Schmid, J .
PLANT AND SOIL, 1999, 215 (01) :47-55
[4]  
Brenner A. J., 1991, IAHS Publication, P375
[5]  
Burgess SSO, 2000, TREE PHYSIOL, V20, P909
[6]   THERMAL MEASUREMENTS OF SAP FLUX IN TRUNKS AND ROOTS AND HYDROUS BEHAVIOR OF TREES .1. THEORETICAL-ANALYSIS OF THE ERRORS IN SAP-FLUX ESTIMATIONS AND MEASUREMENT VALIDATION IN THE PRESENCE OF EXTERNAL THERMAL-GRADIENTS [J].
CABIBEL, B ;
DO, F .
AGRONOMIE, 1991, 11 (08) :669-678
[7]   NEW METHOD OF SAP FLOW-RATE DETERMINATION IN TREES [J].
CERMAK, J ;
DEML, M ;
PENKA, M .
BIOLOGIA PLANTARUM, 1973, 15 (03) :171-178
[8]   THE COMPENSATION OF NATURAL TEMPERATURE-GRADIENT AT THE MEASURING POINT DURING THE SAP FLOW-RATE DETERMINATION IN TREES [J].
CERMAK, J ;
KUCERA, J .
BIOLOGIA PLANTARUM, 1981, 23 (06) :469-471
[9]   3 METHODS FOR MONITORING THE GAS-EXCHANGE OF INDIVIDUAL TREE CANOPIES - VENTILATED-CHAMBER, SAP-FLOW AND PENMAN-MONTEITH MEASUREMENTS ON EVERGREEN OAKS [J].
GOULDEN, ML ;
FIELD, CB .
FUNCTIONAL ECOLOGY, 1994, 8 (01) :125-135
[10]   A NEW METHOD OF SAP FLOW MEASUREMENT IN TREE STEMS [J].
GRANIER, A .
ANNALES DES SCIENCES FORESTIERES, 1985, 42 (02) :193-200