High-throughput flow cytometric DNA fragment sizing

被引:39
作者
Van Orden, A [1 ]
Keller, RA [1 ]
Ambrose, WP [1 ]
机构
[1] Los Alamos Natl Lab, Biosci Div, MS M888, Los Alamos, NM 87545 USA
关键词
D O I
10.1021/ac990782i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rate of detection and sizing of individual fluorescently labeled DNA fragments in conventional single-molecule now cytometry (SMFC) is limited by optical saturation, photon-counting statistics, and fragment overlap to similar to 100 fragments/s. We have increased the detection rate for DNA fragment sizing in SMFC to similar to 2000 fragments/s by parallel imaging of the fluorescence from individual DNA molecules, stained with a fluorescent intercalating dye, as they passed through a planar sheet of excitation laser light, resulting in order of magnitude improvements in the measurement speed and the sample throughout compared to conventional SMFC. Fluorescence bursts were measured from a fM solution of DNA fragments ranging in size from 7 to 154 kilobase pairs. A data acquisition time of only a few seconds was sufficient to determine the DNA fragment size distribution. A linear relationship between the number of detected photons per burst and the DNA fragment size was confirmed. Application of this parallel fluorescence imaging method will lead to improvements in the speed, throughput, and sensitivity of other types of flow-based analyses involving the study of single molecules, chromosomes, cells, etc.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 36 条
[1]   Polarization effects in flow cytometric DNA sizing [J].
Agronskaia, A ;
Schins, JM ;
de Grooth, BG ;
Greve, J .
APPLIED OPTICS, 1999, 38 (04) :714-719
[2]  
AMBROSE WP, IN PRESS TOPICS FLUO, V7
[3]  
[Anonymous], CURRENT PROTOCOLS MO
[4]   Infectious disease - PCR detection of bacteria in seven minutes [J].
Belgrader, P ;
Benett, W ;
Hadley, D ;
Richards, J ;
Stratton, P ;
Mariella, R ;
Milanovich, F .
SCIENCE, 1999, 284 (5413) :449-450
[5]   Infrared MALDI mass spectrometry of large nucleic acids [J].
Berkenkamp, S ;
Kirpekar, F ;
Hillenkamp, F .
SCIENCE, 1998, 281 (5374) :260-262
[6]   High-resolution restriction maps of bacterial artificial chromosomes constructed by optical mapping [J].
Cai, WW ;
Jing, JP ;
Irvin, B ;
Ohler, L ;
Rose, E ;
Shizuya, H ;
Kim, UJ ;
Simon, M ;
Anantharaman, T ;
Mishra, B ;
Schwartz, DC .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (07) :3390-3395
[7]  
CANTOR CR, 1988, ANNU REV BIOPHYS BIO, V17, P287
[8]   FLUORESCENCE DETECTION AND SIZE MEASUREMENT OF SINGLE DNA-MOLECULES [J].
CASTRO, A ;
FAIRFIELD, FR ;
SHERA, EB .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :849-852
[9]   SINGLE-MOLECULE ELECTROPHORESIS [J].
CASTRO, A ;
SHERA, EB .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3181-3186
[10]   A microfabricated device for sizing and sorting DNA molecules [J].
Chou, HP ;
Spence, C ;
Scherer, A ;
Quake, S .