Drew-Anderson Technique attenuates systemic inflammatory response syndrome and improves respiratory function after coronary artery bypass grafting

被引:83
作者
Richter, JA
Meisner, H
Tassani, P
Barankay, A
Dietrich, W
Braun, SL
机构
[1] Tech Univ Munich, German Heart Ctr, Dept Anesthesiol, D-8000 Munich, Germany
[2] Tech Univ Munich, German Heart Ctr, Dept Cardiovasc Surg, D-8000 Munich, Germany
关键词
D O I
10.1016/S0003-4975(99)01131-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Cardiopulmonary bypass causes inflammatory reactions leading to organ dysfunction postoperatively. This study was undertaken to determine whether using patients' own lungs as oxygenator in a bilateral circuit (Drew-Anderson Technique) could reduce systemic inflammatory response to cardiopulmonary bypass, improving patients clinical outcome following coronary artery bypass grafting. Methods. A prospective randomized controlled trial involving 30 patients, divided in two groups of 15 patients each, undergoing elective coronary artery bypass grafting, was undertaken. In the Drew-group bilateral extracorporeal circulation using patient's lung as oxygenator was performed. The other patients served as control group, where standard cardiopulmonary bypass procedure was used. Results. pro-inflammatory and anti-inflammatory mediators were measured. Peak concentrations of pro-inflammatory interleukin-6, interleukin-8, were significantly lower in 15 patients undergoing Drew-Anderson Technique compared with the concentrations measured in 15 patients treated with standard cardiopulmonary bypass technique. Differences in patient recovery were analyzed with respect to time of intubation, blood loss, intrapulmonary shunting, oxygenation, and respiratory index. In patients undergoing uncomplicated coronary artery bypass grafting procedures bilateral extracorporeal circulation using the patients' own lung as oxygenator provided significant biochemical and clinical benefit in comparison to the standard cardiopulmonary bypass procedure. Conclusions. This prospective randomized clinical study has demonstrated that exclusion of an artificial oxygenator from cardiopulmonary bypass circuit si,significantly decreases the activation of inflammatory reaction, and that interventions that attenuate this response may result in more favorable clinical outcome. (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 24 条
[1]  
DIETRICH W, 1993, J THORAC CARDIOVASC, V108, P626
[2]   ANTICYTOKINE STRATEGIES IN THE TREATMENT OF THE SYSTEMIC INFLAMMATORY RESPONSE SYNDROME [J].
DINARELLO, CA ;
GELFAND, JA ;
WOLFF, SM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (14) :1829-1835
[3]  
DREW CE, 1959, LANCET, V1, P748
[4]  
Edmunds L H Jr, 1995, Adv Card Surg, V6, P131
[5]   INTERLEUKIN-8 RELEASE AND NEUTROPHIL DEGRANULATION AFTER PEDIATRIC CARDIOPULMONARY BYPASS [J].
FINN, A ;
NAIK, S ;
KLEIN, N ;
LEVINSKY, RJ ;
STROBEL, S ;
ELLIOTT, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 105 (02) :234-241
[6]  
GLENVILLE B, 1986, LANCET, V4, P1005
[7]  
HAEFFNERCAVAILLON N, 1989, J THORAC CARDIOV SUR, V98, P1100
[8]   The systemic inflammatory response to cardiopulmonary bypass: Pathophysiological, therapeutic, and pharmacological considerations [J].
Hall, RI ;
Smith, MS ;
Rocker, G .
ANESTHESIA AND ANALGESIA, 1997, 85 (04) :766-782
[9]  
HENNEIN HA, 1994, J THORAC CARDIOV SUR, V108, P626
[10]   The influence of cardiopulmonary bypass on cytokines and cell-cell communication [J].
Hill, GE ;
Whitten, CW ;
Landers, DF .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (03) :367-375