Lesions entirely removed during stereotactic biopsy: Preoperative localization on the basis of mammographic landmarks and feasibility of freehand technique-initial experience

被引:16
作者
Brenner, RJ [1 ]
机构
[1] St Johns Hlth Ctr, Joyce Eisenberg Keefer Breast Ctr, John Wayne Canc Inst, Santa Monica, CA 90404 USA
关键词
biopsies; technology; breast; biopsy; breast neoplasms; diagnosis; stereotaxis;
D O I
10.1148/radiology.214.2.r00ja18585
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Seven patients with mammographic lesions entirely removed at percutaneous core needle biopsy that required wider excision underwent freehand localization of the site of the prior lesion with orthogonal acid reproducible mammographic landmarks to guide needle placement. Successful excision was accomplished in all cases, as evidenced by similar histopathologic findings, fibrin bands or collagen, and core needle biopsy tract at microscopy.
引用
收藏
页码:585 / 590
页数:6
相关论文
共 30 条
[1]   Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model [J].
Berg, WA ;
Krebs, TL ;
Campassi, C ;
Magder, LS ;
Sun, CCJ .
RADIOLOGY, 1997, 205 (01) :203-208
[2]  
Brenner RJ, 1997, ACAD RADIOL, V4, P419
[3]   Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy [J].
Brenner, RJ ;
Fajardo, L ;
Fisher, PR ;
Dershaw, DD ;
Evans, WP ;
Bassett, L ;
Feig, S ;
Mendelson, E ;
Jackson, V ;
Margolin, FR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :341-346
[4]   TRANSGRESSION OF LOCALIZING WIRE INTO THE PLEURAL CAVITY PRIOR TO MAMMOGRAPHY [J].
BRISTOL, JB ;
JONES, PA .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (638) :139-140
[5]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[6]  
Burbank F, 1997, AM SURGEON, V63, P988
[7]   Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization [J].
Burbank, F ;
Forcier, N .
RADIOLOGY, 1997, 205 (02) :407-415
[8]   LOCALIZATION AND EXCISION OF OCCULT BREAST-LESIONS [J].
CHETTY, U ;
KIRKPATRICK, AE ;
ANDERSON, TL ;
LAMB, J ;
ROBERTS, MM ;
HUMENIUK, V ;
FORREST, APM .
BRITISH JOURNAL OF SURGERY, 1983, 70 (10) :607-610
[9]   Stereotactic core breast biopsy of a minimal carcinoma complicated by a large hematoma: A management dilemma [J].
Deutch, BM ;
Schwartz, MR ;
Fodera, T ;
Ray, DM .
RADIOLOGY, 1997, 202 (02) :431-433
[10]   NONPALPABLE BREAST-LESIONS - CORRELATION OF STEREOTAXIC LARGE-CORE NEEDLE-BIOPSY AND SURGICAL BIOPSY RESULTS [J].
ELVECROG, EL ;
LECHNER, MC ;
NELSON, MT .
RADIOLOGY, 1993, 188 (02) :453-455