A new ultrasound-guided esophageal variceal pressure-measuring device

被引:16
作者
Miller, LS [1 ]
Dai, Q [1 ]
Thomas, A [1 ]
Chung, CY [1 ]
Park, J [1 ]
Irizarry, S [1 ]
Nguyen, T [1 ]
Thangada, V [1 ]
Miller, ES [1 ]
Kim, JK [1 ]
机构
[1] Temple Univ Hosp & Med Sch, Dept Gastroenterol, Philadelphia, PA 19140 USA
关键词
D O I
10.1111/j.1572-0241.2004.30177.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVE: To develop a noninvasive method and device to determine intravariceal pressure and variceal wall tension by measuring the variables of the Laplace equation and test this device in a model of esophageal varices. METHODS: Two variceal pressure measurement devices were constructed. The first device consists of an Olympus 20 MHz ultrasound transducer placed next to a latex balloon catheter attached to a pressure transducer. The second device was constructed by placing the same ultrasound transducer inside a latex condom balloon attached to a pressure transducer. These pressure measurement devices were tested blindly in varix models with different intravariceal pressures, by inflating the balloon to flatten the varix models. Each variceal pressure was measured 10 times by two separate investigators blinded to the actual pressures. The mean intravariceal pressures were calculated. The variceal models were made of a latex balloon filled with water and coffeemate. RESULTS: The correlation coefficient between the actual and measured varix pressures for both devices was 0.99. The percent error ranged from 0 to 10%. The correlation coefficient between the investigators making the blinded measurements for both devices was 0.98. CONCLUSION: Two pressure-measuring devices were developed to determine intravariceal pressure in a model varix system. These devices demonstrate a low percent error and a high correlation to the actual variceal pressures with low intra- and interobserver variability. These devices have the potential to measure all the variables of the Laplace equation for wall tension. We plan to test these devices in human subjects.
引用
收藏
页码:1267 / 1273
页数:7
相关论文
共 12 条
[1]  
ATTI EA, 1999, GUT, V45, P618
[2]   NONINVASIVE MEASUREMENT OF THE PRESSURE OF ESOPHAGEAL-VARICES USING AN ENDOSCOPIC GAUGE - COMPARISON WITH MEASUREMENTS BY VARICEAL PUNCTURE IN PATIENTS UNDERGOING ENDOSCOPIC SCLEROTHERAPY [J].
BOSCH, J ;
BORDAS, JM ;
RIGAU, J ;
VIOLA, C ;
MASTAI, R ;
KRAVETZ, D ;
NAVASA, M ;
RODES, J .
HEPATOLOGY, 1986, 6 (04) :667-672
[3]  
GENECIN P, 1993, PORTAL HYPERTENSION
[4]   EXPERIMENTAL EVALUATION OF AN ENDOSCOPIC BALLOON FOR MANOMETRY OF ESOPHAGEAL-VARICES [J].
GERTSCH, P ;
WHEATLEY, AM ;
MAIBACH, R ;
MADDERN, GJ ;
VAUTHEY, JN .
GASTROENTEROLOGY, 1991, 101 (06) :1692-1700
[5]   MANOMETRY OF ESOPHAGEAL-VARICES - COMPARISON OF AN ENDOSCOPIC BALLOON TECHNIQUE WITH NEEDLE PUNCTURE [J].
GERTSCH, P ;
FISCHER, G ;
KLEBER, G ;
WHEATLEY, AM ;
GEIGENBERGER, G ;
SAUERBRUCH, T .
GASTROENTEROLOGY, 1993, 105 (04) :1159-1166
[6]   PRESSURE OF INTRAESOPHAGEAL VARICES ASSESSED BY FINE NEEDLE PUNCTURE - ITS RELATION TO ENDOSCOPIC SIGNS AND SEVERITY OF LIVER-DISEASE IN PATIENTS WITH CIRRHOSIS [J].
KLEBER, G ;
SAUERBRUCH, T ;
FISCHER, G ;
PAUMGARTNER, G .
GUT, 1989, 30 (02) :228-232
[7]   A new device for measuring esophageal variceal pressure [J].
Miller, ES ;
Kim, JK ;
Gandehok, J ;
Hara, M ;
Dai, Q ;
Malik, A ;
Miller, A ;
Miller, L .
GASTROINTESTINAL ENDOSCOPY, 2002, 56 (02) :284-291
[8]   Variceal pressure is a factor predicting the risk of a first variceal bleeding: A prospective cohort study in cirrhotic patients [J].
Nevens, F ;
Bustami, R ;
Scheys, I ;
Lesaffre, E ;
Fevery, J .
HEPATOLOGY, 1998, 27 (01) :15-19
[9]   Assessment of variceal pressure by continuous non-invasive endoscopic registration: A placebo controlled evaluation of the effect of terlipressin and octreotide [J].
Nevens, F ;
VanSteenbergen, W ;
Yap, SH ;
Fevery, J .
GUT, 1996, 38 (01) :129-134
[10]  
RIGAU J, 1989, GASTROENTEROLOGY, V96, P873