Measuring muscular strength of the lower limbs by hand-held dynamometer: A standard protocol

被引:116
作者
Bandinelli, S [1 ]
Benvenuti, E [1 ]
Del Lungo, I [1 ]
Baccini, M [1 ]
Benvenuti, F [1 ]
Di Iorio, A [1 ]
Ferrucci, L [1 ]
机构
[1] Osped Fraticini, Ist Ortoped Toscano, INRCA,Natl Res Inst, Dept Geriatr, I-50125 Florence, Italy
关键词
aging; hand-held dynamometer; muscle strength;
D O I
10.1007/BF03339802
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
The aim of this study is to describe the reliability of measuring maximal strength of eight muscle groups of the lower limb by a handheld dynamometer, according to a standard assessment protocol. The study population consisted of 26 patients (14 males and 12 females; age range 60-90 years) admitted to a geriatric hospital. Multiple assessments of muscle strength by two different examiners were compared to estimate test-retest and inter-rater reliability. The range of strength evaluated across the eight muscle groups was 2.1-29.8 Kg/force. Overall, short-term (same day) and long-term (one week apart) test-retest and inter-rater reliability were very high, with 60% of the intraclass correlation coefficient values above 0.8, and the majority above 0.7. No significant differences in strength were found comparing the left and the right side of each muscle group. Differences between values collected in the same subject by two different examiners, and by the same examiner at different points in time were similar, not influenced by the average strength of the muscle group, and significantly larger for long-term than for short-term comparisons. By using a standardized measurement protocol, reliable measurements of muscle strength can be obtained by a hand-held dynamometer in frail older persons. (Aging Clin. Exp. Res. 11: 287-293, 1999) (C)1999, Editrice Kurtis.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 24 条
[1]  
AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
[2]  
AGRE JC, 1988, ARCH PHYS MED REHAB, V69, P273
[3]  
ALEXANDER MJL, 1990, ARCH PHYS MED REHAB, V71, P334
[4]  
Amundsen L., 1990, Muscle Strength Testing. Instrument and Non-instrumented Systems
[5]  
BEASLEY W C, 1961, Arch Phys Med Rehabil, V42, P398
[6]   INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[7]  
BOHANNON RW, 1987, AM J PHYS MED REHAB, V66, P213
[8]  
BYL N N, 1988, Journal of Orthopaedic and Sports Physical Therapy, V9, P399
[9]   MINI-MENTAL STATE - PRACTICAL METHOD FOR GRADING COGNITIVE STATE OF PATIENTS FOR CLINICIAN [J].
FOLSTEIN, MF ;
FOLSTEIN, SE ;
MCHUGH, PR .
JOURNAL OF PSYCHIATRIC RESEARCH, 1975, 12 (03) :189-198
[10]   DEVELOPMENT AND VALIDATION OF A PHYSICAL PERFORMANCE INSTRUMENT FOR THE FUNCTIONALLY IMPAIRED ELDERLY - THE PHYSICAL-DISABILITY INDEX (PDI) [J].
GERETY, MB ;
MULROW, CD ;
TULEY, MR ;
HAZUDA, HP ;
LICHTENSTEIN, MJ ;
BOHANNON, R ;
KANTEN, DN ;
ONEIL, MB ;
GORTON, A .
JOURNALS OF GERONTOLOGY, 1993, 48 (02) :M33-M38