Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters

被引:45
作者
Huitema, RB
Hof, AL
Postema, K
机构
[1] Univ Groningen Hosp, Dept Rehabil Med, NL-9713 GZ Groningen, Netherlands
[2] Univ Groningen, Inst Human Movement Sci, NL-9713 AV Groningen, Netherlands
关键词
gait analysis; ultrasonics; spatial and temporal gait parameters; pathological gait; walking;
D O I
10.1016/S0021-9290(02)00032-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the propagation delay of sound when transmitted in air, this system is able to record the position of the subjects' feet. A small ultrasonic receiver is attached to both shoes of the subject while a transmitter is placed stationary on the floor. Four healthy subjects were used to test the device. Subtracting positions of the foot with zero velocity yielded step and stride length. The duration of stance and swing phase was calculated from heel-strike and toe-off. Comparison with data obtained from foot contact switches showed that applying two relative thresholds to the speed graph of the foot could reliably generate heel-strike and toe-off. Although the device is tested on healthy subjects in this study, it promises to be extremely valuable in examining pathological gait. When gait is asymmetrical, walking speed is not constant or when patients do not completely lift their feet, most existing devices will fail to correctly assess the proper gait parameters. Our device does not have this shortcoming and it will accurately demonstrate asymmetries and variations in the patient's gait. As an example, the recording of a left hemiplegic patient is presented in the discussion. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:837 / 842
页数:6
相关论文
共 9 条
[1]
[Anonymous], 1981, Human walking
[2]
MEASUREMENT OF THE TEMPORAL AND SPATIAL PARAMETERS OF GAIT USING A MICROCOMPUTER BASED SYSTEM [J].
CROUSE, J ;
WALL, JC ;
MARBLE, AE .
JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (01) :64-68
[3]
DeQuervain IAK, 1996, J BONE JOINT SURG AM, V78A, P1506
[4]
THE SELECTION OF A STANDARD CONVENTION FOR ANALYZING GAIT DATA-BASED ON THE ANALYSIS OF RELEVANT BIOMECHANICAL FACTORS [J].
DEVITA, P .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :501-508
[5]
CLINICAL GAIT ASSESSMENT IN THE NEUROLOGICALLY IMPAIRED - RELIABILITY AND MEANINGFULNESS [J].
HOLDEN, MK ;
GILL, KM ;
MAGLIOZZI, MR ;
NATHAN, J ;
PIEHLBAKER, L .
PHYSICAL THERAPY, 1984, 64 (01) :35-40
[6]
DIFFERENT TYPES OF DISTURBED MOTOR CONTROL IN GAIT OF HEMIPARETIC PATIENTS [J].
KNUTSSON, E ;
RICHARDS, C .
BRAIN, 1979, 102 (JUN) :405-430
[7]
The validity and reliability of the GAITRite system's measurements: A preliminary evaluation [J].
McDonough, AL ;
Batavia, M ;
Chen, FC ;
Kwon, S ;
Ziai, J .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (03) :419-425
[8]
Limb locomotion - speed distribution analysis as a new method for stance phase detection [J].
Peham, C ;
Scheidl, M ;
Licka, T .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1119-1124
[9]
RIGAS C, 1984, PROSTHET ORTHOT INT, V8, P130