The BWM spinal fixator system - A preliminary report of a 2-year prospective, international multicenter study in a range of indications requiring surgical intervention for bone grafting and pedicle screw fixation

被引:16
作者
Bailey, SI
Bartolozzi, P
Bertagnoli, R
Boriani, S
vanBeurden, AFA
Cross, AT
Friedl, HP
Gurr, KR
Halm, H
Kruls, HJA
MetzStavenhagen, P
Schulze, KJ
机构
[1] UNIV WESTERN ONTARIO, DEPT ORTHOPAED, VICTORIA HOSP, LONDON, ON, CANADA
[2] POLICLIN BORGO ROMA, CLIN ORTOPED VERONA, VERONA, ITALY
[3] UNIV GOTTINGEN, CHIRURG KLIN, ORTHOPAD ABT, D-3400 GOTTINGEN, GERMANY
[4] IGNATIUS ZIEKENHUIS, DEPT ORTHOPAED, BREDA, NETHERLANDS
[5] SUNDERLAND DIST GEN HOSP, DEPT ORTHOPAED, SUNDERLAND, DURHAM, ENGLAND
[6] UNIV SPITAL ZURICH, UNFALLCHIRURG KLIN, ZURICH, SWITZERLAND
[7] UNIV MUNSTER, KLIN & POLIKLIN ALLGEMEINE ORTHOPAD, MUNSTER, GERMANY
[8] WERNER WICKER KLIN, SKOLIOSE DEPT 2, BAD WILDUNGEN, GERMANY
[9] MED ACAD CARL GUSTAV CARUS, ORTHOPAD KLIN, D-8019 DRESDEN, GERMANY
关键词
bone grafting; degenerative disease; failed back; pedicle screw fixation; pseudarthrosis; spinal fracture; spondylitis; spondylolisthesis;
D O I
10.1097/00007632-199609010-00016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective, international, multi-center study of 400 patients who received the BWM fixator system. Objectives. To assess the effectiveness and safety of the system in the management of various conditions requiring spinal fixation and bone grafting. Summary of Background Data. The BWM system was developed for the management of spinal instability of all etiologies occurring in the thoracic, thoracolumbar, and lumbosacral spine. Methods. Patients with fracture, tumor, spondylolisthesis, spondylitis, failed back, or other degenerative conditions of the spine received the BWM instrumentation as described in the study literature and were regularly reviewed for 2 years. Results. The results from the first 200 patients to complete the study showed an overall graft fusion rate of 94% (95% confidence interval: 91.3%-97.6%). There were marked improvements in measures of functional ability (P < 0.001, Wilcoxon test). Before surgery, less than half the patients were capable of outdoor activity. At 2 years, 80% were able to undertake outdoor activity. There were few perioperative difficulties reported. Postoperative complications associated with major surgery were seen in 18% patients. There were 23 (2.6%) pedicle screw failures, including two loosenings, and 13 (2.5%) spacer element failures, including three loosenings. Conclusions. Clinical failure was not necessarily a consequence of component failure. The BWM fixator provided excellent stabilization during the process of bone graft consolidation. The risks of complication or component failure were no higher than those associated with similar devices.
引用
收藏
页码:2006 / 2015
页数:10
相关论文
共 13 条
  • [1] ABITBOL JJ, 1994, ADV ORTHOP SURG, V17, P345
  • [2] Chen J Y, 1992, Orthop Rev, V21, P75
  • [3] CRAWFORD RJ, 1994, EUR SPINE J, V3, P44
  • [4] COMPLICATIONS OF LUMBAR SPINAL-FUSION WITH TRANSPEDICULAR INSTRUMENTATION
    DAVNE, SH
    MYERS, DL
    [J]. SPINE, 1992, 17 (06) : S184 - S189
  • [5] TRANSPEDICULAR SCREW-ROD FIXATION OF THE LUMBAR SPINE - OPERATIVE TECHNIQUE AND OUTCOME IN 104 CASES
    DICKMAN, CA
    FESSLER, RG
    MACMILLAN, M
    HAID, RW
    [J]. JOURNAL OF NEUROSURGERY, 1992, 77 (06) : 860 - 870
  • [6] COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS
    ESSES, SI
    SACHS, BL
    DREYZIN, V
    [J]. SPINE, 1993, 18 (15) : 2231 - 2239
  • [7] POSTERIOR LUMBAR INTERBODY FUSION - A 2-YEAR FOLLOW-UP OF 238 PATIENTS
    GILL, K
    BLUMENTHAL, SL
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 : 108 - 110
  • [8] MCAFEE PC, 1991, SPINE, V16, pS422
  • [9] RANSOM M, 1994, SPINE, V19, P2702
  • [10] Rommens P M, 1995, Eur Spine J, V4, P104