Modulation of the separation selectivity of inorganic anions in electrostatic ion chromatography using acidic eluents

被引:11
作者
Hu, WZ
Haddad, PR
Tanakar, K
Hasebe, K
机构
[1] Univ Tasmania, Sch Chem, Hobart, Tas 7001, Australia
[2] Natl Ind Res Inst Nagoya, Nagoya, Aichi 4628510, Japan
[3] Hokkaido Univ, Grad Sch Environm & Earth Sci, Sapporo, Hokkaido 0600810, Japan
关键词
D O I
10.1039/a909684a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation selectivity for inorganic anions in electrostatic ion chromatography (EIC) was modulated by control of the concentration of H+ in the eluent. For example, in the separation of NO2-, Br- and NO3 using H2SO4 as eluent, the elution order could be NO2- < Br- < NO3-; Br- < NO2- < NO3-; or Br- < NO3- < NO2-, depending on the concentration of H2SO4 in the range 1-30 mM. This behaviour is explained by protonation of the sulfonate functional groups of the stationary phase and the resultant changes in the binary electrical double layer (EDL) established at the charge centres of the zwitterionic stationary phase. The elution order for analyte anions was governed by the balance between the cation-EDL and anion-EDL, which is determined by the concentration of H+ in the eluent and results in varying degrees of ion-exchange contributing to a mixed-mode retention mechanism. It was also found in this study that addition of a small amount of perchlorate ion into the eluent was an effective means to elute very polarizable anions (e.g., I-, and SCN-). This was attributed to the high propensity for ClO4- to enter the anion-EDL on the positively charged quaternary ammonium groups of the zwitterionic stationary phase.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 9 条
[1]  
HADDAD PR, 1974, ION CHROMATOGRAPHY P
[2]  
HIROGAWA T, 1983, J CHROMATOGR, P45
[3]   Electrostatic ion chromatography using dilute electrolytes as eluents: a new method for separation of anions [J].
Hu, WZ ;
Haddad, PR .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :317-320
[4]   Electrostatic ion chromatography using hydroxide solutions as mobile phase with suppressed conductivity detection [J].
Hu, WZ ;
Haddad, PR ;
Hasebe, K ;
Tanaka, K .
ANALYTICAL COMMUNICATIONS, 1999, 36 (08) :309-312
[5]   Direct determination of bromide, nitrate, and iodide in saline matrixes using electrostatic ion chromatography with an electrolyte as eluent [J].
Hu, WZ ;
Haddad, PR ;
Hasebe, K ;
Tanaka, K ;
Tong, P ;
Khoo, C .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1617-1620
[6]   ELECTROSTATIC ION CHROMATOGRAPHY [J].
HU, WZ ;
TAKEUCHI, T ;
HARAGUCHI, H .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2204-2208
[7]   Electrostatic ion chromatography [J].
Hu, WZ ;
Haddad, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (02) :73-79
[8]   Covalently bonded polymeric zwitterionic stationary phase for simultaneous separation of inorganic cations and anions [J].
Jiang, W ;
Irgum, K .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :333-344
[9]   LIQUID-CHROMATOGRAPHIC SEPARATION OF INORGANIC ANIONS ON AN ALUMINA COLUMN [J].
SCHMITT, GL ;
PIETRZYK, DJ .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2247-2253