The pattern of a spatial structure that repeats itself independently of the scale of magnification or resolution is often characterized by a fractal dimension (D). Two-dimensional low-pass filtering, which may serve as a method to assess D, was applied to functional images of pulmonary perfusion measured by positron emission tomography. The corner frequency of a low-pass filter is inversely proportional to the resolution scale. The method was applied to three types of images: random noise images, synthetic fractal images, and positron emission tomographic images of pulmonary perfusion. images were processed with two-dimensional lowpass filters of decreasing corner frequencies, and a spatial heterogeneity index, the coefficient of variation, was calculated for each low-pass-filtered image. The natural logarithm of the coefficient of variation scaled linearly with the natural logarithm of the resolution scale for the PET images studied (average R-2 = 0.99). D ranged-from 1.25 to 1.36 for the residual distribution of pulmonary perfusion after vertical gradients were removed by linear regression. D of the same data without removal of vertical gradients ranged from 1.11 to 1.14, but the fractal plots had systematic deviations from linearity and a lower linear correlation coefficient (R-2 = 0.96). The method includes all data in the lung field and is insensitive to the effects of misregistration. We conclude that low-pass filtering offers new insights into the interpretation of D of two-dimensional functional images as a measure of the frequency content of spatial heterogeneity.
引用
收藏
页码:1365 / 1373
页数:9
相关论文
共 24 条
[1]   Measurement of pulmonary blood flow by fractal analysis of flow heterogeneity in isolated canine lungs [J].
Barman, SA ;
McCloud, LL ;
Catravas, JD ;
Ehrhart, IC .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (05) :2039-2045
[2]  
Bassingthwaighte J. B., 1994, FRACTAL PHYSL, DOI DOI 10.1007/978-1-4614-7572-9
[3]  
BASSINGTHWAIGHTE JB, 1988, NEWS PHYSIOL SCI, V3, P5
[4]  
BENHAMON CL, 1989, J BONE MINER RES, V9, P1909
[5]   EFFECTS OF PULMONARY BLOOD-FLOW ON THE FRACTAL NATURE OF FLOW HETEROGENEITY IN SHEEP LUNGS [J].
CARUTHERS, SD ;
HARRIS, TR .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (03) :1474-1479
[7]  
Feder J., 1988, FRACTALS
[8]   FRACTAL MODELING OF PULMONARY BLOOD-FLOW HETEROGENEITY [J].
GLENNY, RW ;
ROBERTSON, HT .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (03) :1024-1030
[9]   APPLICATIONS OF FRACTAL ANALYSIS TO PHYSIOLOGY [J].
GLENNY, RW ;
ROBERTSON, HT ;
YAMASHIRO, S ;
BASSINGTHWAIGHTE, JB .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (06) :2351-2367
[10]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79