Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer

被引:304
作者
Makarov, Alexander [1 ]
Denisov, Eduard [1 ]
Lange, Oliver [1 ]
Horning, Stevan [1 ]
机构
[1] Thermo Elecron Bremen GmbH, D-28199 Bremen, Germany
关键词
D O I
10.1016/j.jasms.2006.03.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Using a novel orbitrap mass spectrometer, the authors investigate the dynamic range over which accurate masses can be determined (extent of mass accuracy) for short duration experiments typical for LC/MS. A linear ion trap is used to selectively fill an intermediate ion storage device (C-trap) with ions of interest, following which the ensemble of ions is injected into an orbitrap mass analyzer and analyzed using image Current detection and fast Fourier transformation. Using this technique, it is possible to generate ion populations with intraspectrum intensity ranges up to 10(+). All measurements (including ion accumulation and image current detection) were performed in less than 1 s at a resolving power of 30,000. It was shown that 5-ppm mass accuracy of the orbitrap mass analyzer is reacted with > 95% probability at a dynamic range of more than 5000, which is at least an order of magnitude higher than typical values for time-of-flight instruments. Due to the high resolving power of the orbitrap, accurate mass of an ion could be determined when the signal was reliably distinguished from noise (S/Np-p > 2...3).
引用
收藏
页码:977 / 982
页数:6
相关论文
共 18 条
[1]   Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer [J].
Blom, KF .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :715-719
[2]  
BROWN CE, 1990, SPECTROSC WORLD, V1, P25
[3]  
CHEN L, 1986, CHEMOMETRICS INTELLI, V1, P51
[4]   A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer [J].
Colombo, M ;
Sirtori, FR ;
Rizzo, V .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) :511-517
[5]   Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR [J].
Easterling, ML ;
Mize, TH ;
Amster, IJ .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :624-632
[6]  
FJELDSTED J, 2003, 59890373EN
[7]   THEORY OF SPACE-CHARGE SHIFT OF ION-CYCLOTRON RESONANCE FREQUENCIES [J].
JEFFRIES, JB ;
BARLOW, SE ;
DUNN, GH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 54 (1-2) :169-187
[8]   SPACE-CHARGE EFFECTS IN FOURIER-TRANSFORM MASS-SPECTROMETRY - MASS CALIBRATION [J].
LEDFORD, EB ;
REMPEL, DL ;
GROSS, ML .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2744-2748
[9]   EXPERIMENTAL-DETERMINATION OF THE NUMBER OF TRAPPED IONS, DETECTION LIMIT, AND DYNAMIC-RANGE IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
LIMBACH, PA ;
GROSSHANS, PB ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (02) :135-140
[10]   Electrostatic axially harmonic orbital trapping: A high-performance technique of mass analysis [J].
Makarov, A .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1156-1162