BSCC Code of Practice - fine needle aspiration cytology

被引:65
作者
Kocjan, G. [2 ]
Chandra, A. [1 ]
Cross, P. [3 ]
Denton, K. [4 ]
Giles, T. [5 ]
Herbert, A. [1 ]
Smith, P. [5 ]
Remedios, D. [6 ]
Wilson, P. [7 ]
机构
[1] St Thomas Hosp, Dept Histopathol, London SE1 7EH, England
[2] Univ Coll London Hosp, Dept Histopathol, London, England
[3] Queen Elizabeth Hosp, Dept Histopathol, Gateshead, England
[4] Southmead Hosp, Dept Histopathol, Bristol, Avon, England
[5] Royal Liverpool Univ Hosp, Dept Histopathol, Liverpool, Merseyside, England
[6] NW London Hosp, Dept Radiol, Middlesex, England
[7] Univ London St Georges Hosp, Dept Histopathol, London, England
关键词
The British Society for Clinical Cytology; Code of Practice; fine needle aspiration (FNA); non-gynaecological cytology; cytopathology; guidelines; image-guided FNA; ESOPHAGEAL ENDOSCOPIC ULTRASOUND; PATIENT DIAGNOSIS SERVICE; COST-EFFECTIVENESS; BREAST-LESIONS; FNA; ACCURACY; CANCER; AUDIT; HEAD; MANAGEMENT;
D O I
10.1111/j.1365-2303.2009.00709.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
BSCC Code of Practice - fine needle aspiration cytology The British Society for Clinical Cytology Code of Practice on fine needle aspiration cytology complements that on exfoliative cytopathology, which was published in the last issue (Cytopathology 2009;20:211-23). Both have been prepared with wide consultation within and outside the BSCC and have been endorsed by the Royal College of Pathologists. A separate code of practice for gynaecological cytopathology is in preparation. Fine needle aspiration (FNA) cytology is an accepted first line investigation for mass lesions, which may be targeted by palpation or a variety of imaging methods. Although FNA cytology has been shown to be a cost-effective, reliable technique its accurate interpretation depends on obtaining adequately cellular samples prepared to a high standard. Its accuracy and cost-effectiveness can be seriously compromised by inadequate samples. Although cytopathologists, radiologists, nurses or clinicians may take FNAs, they must be adequately trained, experienced and subject to regular audit. The best results are obtained when a pathologist or an experienced and trained biomedical scientist (cytotechnologist) provides immediate on-site assessment of sample adequacy whether or not the FNA requires image-guidance. This COP provides evidence-based recommendations for setting up FNA services, managing the patients, taking the samples, preparing the slides, collecting material for ancillary tests, providing rapid on-site assessment, classifying the diagnosis and providing a final report. Costs, cost-effectiveness and rare complications are taken into account as well as the time and resources required for quality control, audit and correlation of cytology with histology and outcome. Laboratories are expected to have an effective quality management system conforming to the requirements of a recognised accreditation scheme such as Clinical Pathology Accreditation (UK) Ltd.
引用
收藏
页码:283 / 296
页数:14
相关论文
共 42 条
[1]  
AGARWAL PK, 1989, ACTA CYTOL, V33, P652
[2]  
[Anonymous], CYTOPATHOLOGY ANN 19
[3]  
[Anonymous], IMPR OUTC HEAD NECK
[4]  
*BMA, 2003, JOB PLANN 2003 CONS
[5]  
Boerner S, 1999, CANCER CYTOPATHOL, V87, P19, DOI 10.1002/(SICI)1097-0142(19990225)87:1<19::AID-CNCR4>3.0.CO
[6]  
2-K
[7]   COST-EFFECTIVENESS OF A FINE NEEDLE ASPIRATION CLINIC [J].
BROWN, LA ;
COGHILL, SB .
CYTOPATHOLOGY, 1992, 3 (05) :275-280
[8]   Ultrasound-guided fine needle aspiration cytology in the diagnosis and management of thyroid nodules [J].
Cai, X. J. ;
Valiyaparambath, N. ;
Nixon, P. ;
Waghorn, A. ;
Giles, T. ;
Helliwell, T. .
CYTOPATHOLOGY, 2006, 17 (05) :251-256
[9]   Strategies to diagnose lymphoproliferative disorders by fine-needle aspiration by using ancillary studies [J].
Caraway, NP .
CANCER CYTOPATHOLOGY, 2005, 105 (06) :432-442
[10]   Fabrication of pre-determined shape of bone segment with collagen-hydroxyapatite scaffold and autogenous platelet-rich plasma [J].
Chang, Shih-Hsin ;
Hsu, Yuan-Ming ;
Wang, Yng Jiin ;
Tsao, Yeou-Ping ;
Tung, Kwan-Yi ;
Wang, Tao-Yuan .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (01) :23-31