Picosecond Raman spectroscopy with a fast intensified CCD camera for depth analysis of diffusely scattering media

被引:46
作者
Ariese, Freek [1 ]
Meuzelaar, Heleen [1 ]
Kerssens, Marleen M. [1 ]
Buijs, Joost B. [1 ]
Gooijer, Cees [1 ]
机构
[1] Vrije Univ Amsterdam, Ctr Laser, Dept Analyt Chem & Appl Spect, Amsterdam, Netherlands
关键词
COUPLED-DEVICE CAMERA; FLUORESCENCE REJECTION; NUMERICAL SIMULATIONS; PHOTON MIGRATION; CALCIFICATIONS; MICROSCOPY;
D O I
10.1039/b821437a
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A spectroscopic depth profiling approach is demonstrated for layers of non-transparent, diffusely scattering materials. The technique is based on the temporal discrimination between Raman photons emitted from the surface and Raman photons originating from a deeper layer. Excitation was carried out with a frequency-doubled, 3 ps Ti:sapphire laser system (398 nm; 76 MHz repetition rate). Time-resolved detection was carried out with an intensified CCD camera that can be gated with a 250 ps gate width. The performance of the system was assessed using 1 mm and 2 mm pathlength cuvettes with powdered PMMA and trans-stilbene (TS) crystals, respectively, or solid white polymer blocks: Arnite (polyethylene terephthalate), Delrin (polyoxymethylene), polythene (polyethylene) and Teflon (polytetrafluoroethylene). These samples were pressed together in different configurations and Raman photons were collected in backscatter mode in order to study the time difference in such media corresponding with several mm of extra net photon migration distance. We also studied the lateral contrast between two different second layers. The results demonstrate that by means of a picosecond laser system and the time discrimination of a gated intensified CCD camera, molecular spectroscopic information can be obtained through a turbid surface layer. In the case of the PMMA/TS two-layer system, time-resolved detection with a 400 ps delay improved the relative intensity of the Raman bands of the second layer with a factor of 124 in comparison with the spectrum recorded with a 100 ps delay (which is more selective for the first layer) and with a factor of 14 in comparison with a non-gated setup. Possible applications will be discussed, as well as advantages/disadvantages over other Raman techniques for diffusely scattering media.
引用
收藏
页码:1192 / 1197
页数:6
相关论文
共 24 条
[1]
Depth profiling of calcifications in breast tissue using picosecond Kerr-gated Raman spectroscopy [J].
Baker, Rebecca ;
Matousek, Pavel ;
Ronayne, Kate Louise ;
Parker, Anthony William ;
Rogers, Keith ;
Stone, Nicholas .
ANALYST, 2007, 132 (01) :48-53
[2]
Brenan CJH, 1996, J RAMAN SPECTROSC, V27, P561, DOI 10.1002/(SICI)1097-4555(199608)27:8<561::AID-JRS7>3.0.CO
[3]
2-9
[4]
Time-resolved fluorescence and photon migration studies in biomedical and model random media [J].
Das, BB ;
Liu, F ;
Alfano, RR .
REPORTS ON PROGRESS IN PHYSICS, 1997, 60 (02) :227-292
[5]
A decade of vibrational micro-spectroscopy of human cells and tissue (1994-2004) [J].
Diem, M ;
Romeo, M ;
Boydston-White, S ;
Miljkovic, M ;
Matthäus, C .
ANALYST, 2004, 129 (10) :880-885
[6]
Novel assessment of bone using time-resolved transcutaneous Raman spectroscopy [J].
Draper, ERC ;
Morris, MD ;
Camacho, NP ;
Matousek, P ;
Towrie, M ;
Parker, AW ;
Goodship, AE .
JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (11) :1968-1972
[7]
Achievements in resonance Raman spectroscopy review of a technique with a distinct analytical chemistry potential [J].
Efremov, Eutim V. ;
Ariese, Freek ;
Gooijer, Cees .
ANALYTICA CHIMICA ACTA, 2008, 606 (02) :119-134
[8]
Fluorescence rejection in resonance Raman spectroscopy using a picosecond-gated intensified charge-coupled device camera [J].
Efremov, Evtim V. ;
Buijs, Joost B. ;
Gooijer, Cees ;
Ariese, Freek .
APPLIED SPECTROSCOPY, 2007, 61 (06) :571-578
[9]
Photon migration in Raman spectroscopy [J].
Everall, N ;
Hahn, T ;
Matousek, P ;
Parker, AW ;
Towrie, M .
APPLIED SPECTROSCOPY, 2004, 58 (05) :591-597
[10]
Picosecond time-resolved Raman spectroscopy of solids: Capabilities and limitations for fluorescence rejection and the influence of diffuse reflectance [J].
Everall, N ;
Hahn, T ;
Matousek, P ;
Parker, AW ;
Towrie, M .
APPLIED SPECTROSCOPY, 2001, 55 (12) :1701-1708