Comparing membrane resistance and absorption performance of three different membranes in a gas absorption membrane contactor

被引:167
作者
Khaisri, Sakarin [2 ]
deMontigny, David [1 ]
Tontiwachwuthikul, Paitoon [1 ]
Jiraratananon, Ratana [2 ]
机构
[1] Univ Regina, Int Test Ctr CO2 Capture, Regina, SK S4S 0A2, Canada
[2] King Mongkuts Univ Technol Thonburi, Dept Chem Engn, Bangkok 10140, Thailand
关键词
Polytetrafluoroethylene; Polypropylene; Polyvinylidene fluoride; Carbon dioxide capture; Membrane contactors; MASS-TRANSFER; CO2; REMOVAL; HOLLOW; POLYPROPYLENE; SEPARATION; SOLVENTS; FILMS;
D O I
10.1016/j.seppur.2008.10.035
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Hollow fiber membrane contactors have been studied extensively in the last decade. Gas absorption membrane (CAM) contactors are a developing technology that overcome the disadvantage of conventional equipment. Three different membranes, including polytetrafluoroethylene (PTFE), polypropylene (PP), and polyvinylidene fluoride (PVDF), were used to test the performance of a GAM system in both physical and chemical absorption studies. in the physical absorption experiments, pure CO2 and de-ionized water were used in the CAM system. A Wilson plot was used to determine the membrane resistance in this work. From the results, the PVDF membrane had a higher CO2 flux than PP membranes and the highest membrane resistance. In the chemical absorption experiments, a simulated flue gas stream (15% CO2 and 85% air) was treated with monoethanolamine (MEA) solutions. Experimental results showed that the CO2 absorption performance can be ranked as PTFE > PVDF > PP. While the PTFE membrane had the best performance in the GAM system, the PVDF membrane is an alternative membrane that could be used. The stability of PTFE and PVDF membranes was tested continuously over 60 h of operation. The PTFE membranes maintained their absorption performance, while the PVDF membranes did not maintain their absorption performance over the operating time. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:290 / 297
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 1975, ASS OFFICIAL ANAL CH
[2]   A study of mass transfer in hollow-fiber membrane contactors - The effect of fiber packing fraction [J].
Asimakopoulou, A. G. ;
Karabelas, A. J. .
JOURNAL OF MEMBRANE SCIENCE, 2006, 282 (1-2) :430-441
[3]   Separation of CO2 from CH4 by using gas-liquid membrane contacting process [J].
Atchariyawut, Supakorn ;
Jiraratananon, Ratana ;
Wang, Rong .
JOURNAL OF MEMBRANE SCIENCE, 2007, 304 (1-2) :163-172
[4]   Effect of membrane structure on mass-transfer in the membrane gas-liquid contacting process using microporous PVDF hollow fibers [J].
Atchariyawut, Supakorn ;
Feng, Chunsheng ;
Wang, Rong ;
Jiraratananon, Ratana ;
Liang, D. T. .
JOURNAL OF MEMBRANE SCIENCE, 2006, 285 (1-2) :272-281
[5]   Comparing the absorption performance of packed columns and membrane contactors [J].
deMontigny, D ;
Tontiwachwuthikul, P ;
Chakma, A .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (15) :5726-5732
[6]   Using polypropylene and polytetrafluoroethylene membranes in a membrane contactor for CO2 absorption [J].
deMontigny, David ;
Tontiwachwuthikul, Paitoon ;
Chakma, Amit .
JOURNAL OF MEMBRANE SCIENCE, 2006, 277 (1-2) :99-107
[7]   Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors [J].
Dindore, VY ;
Brilman, DWF ;
Geuzebroek, FH ;
Versteeg, GF .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) :133-145
[8]   Development of PAMAM dendrimer composite membranes for CO2 separation [J].
Duan, Shuhong ;
Kouketsu, Takayuki ;
Kazama, Shingo ;
Yamada, Koichi .
JOURNAL OF MEMBRANE SCIENCE, 2006, 283 (1-2) :2-6
[9]   A thermodynamic model for wetting free energies from contact angles [J].
Extrand, CW .
LANGMUIR, 2003, 19 (03) :646-649
[10]   Hollow fiber membrane contactors [J].
Gabelman, A ;
Hwang, ST .
JOURNAL OF MEMBRANE SCIENCE, 1999, 159 (1-2) :61-106