Mercury selective membrane electrodes using 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and hexathiacyclooctadecane carriers

被引:101
作者
Mazloum-Ardakani, M [1 ]
Amini, MK [1 ]
Mohammadpoor-Baltork, I [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 81744, Iran
关键词
mercury determination; sensors; mercaptobenzimidazole; mercaptobenzothiazole; hexathiacyclooctadecane;
D O I
10.1016/S0925-4005(00)00300-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, performance, and applications of coated-wire mercury(II)-selective electrodes based on 2-mercaptobenzimidazole (MBIM), 2-mercaptobenzothiazole (MBTH), and hexathiacyclooctadecane (HT18C6) carriers, in plasticized poly(vinyl chloride) (PVC) matrix, are described. The influences of membrane composition and pH on the potentiometric response of the electrodes were investigated. The electrodes exhibit near-Nernstian responses for Hg2+ ion over a wide concentration range (4 to 5 decades of concentration), and a detection limit of about 6 x 10(-7) M (for the electrode based on MBTH). The response time of the electrodes is between 20 and 100 s, depending on the concentration of mercury, and they can be used for about 2 months without any considerable divergence in potential. The proposed sensors revealed good selectivity for Hg2+ in the presence of several metal ions. The best selectivity was observed for the electrode based on MBTH carrier. They were used as indicator electrodes in the potentiometric titration of Hg2+ with EDTA and for the determination of mercury in waste water samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 25 条
[1]   DEVELOPMENT OF A CHEMICALLY MODIFIED ELECTRODE BASED ON CARBON PASTE AND FUNCTIONALIZED SILICA-GEL FOR PRECONCENTRATION AND VOLTAMMETRIC DETERMINATION OF MERCURY(II) [J].
ALEIXO, LM ;
SOUZA, MDB ;
GODINHO, OES ;
NETO, GD ;
GUSHIKEM, Y ;
MOREIRA, JC .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :143-148
[2]  
BAES CF, 1976, HYDROLYSIS CATIONS, P301
[3]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   MERCURY ION-SELECTIVE POLYMERIC MEMBRANE ELECTRODES BASED ON SUBSTITUTED DIAZA CROWN ETHERS [J].
BRZOZKA, Z ;
PIETRASZKIEWICZ, M .
ELECTROANALYSIS, 1991, 3 (08) :855-858
[6]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[7]   SILVER-SELECTIVE MEMBRANE ELECTRODES USING ACYCLIC DITHIA BENZENE DERIVATIVE NEUTRAL CARRIERS - COMPARISON WITH RELATED MACROCYCLIC-COMPOUNDS [J].
CASABO, J ;
FLOR, T ;
ROMERO, MI ;
TEIXIDOR, F ;
PEREZJIMENEZ, C .
ANALYTICA CHIMICA ACTA, 1994, 294 (02) :207-213
[8]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[9]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[10]   MEMBRANE TECHNOLOGY AND DYNAMIC-RESPONSE OF ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES [J].
HUSER, M ;
GEHRIG, PM ;
MORF, WE ;
SIMON, W ;
LINDNER, E ;
JENEY, J ;
TOTH, K ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1380-1386