Use of ultrasound contrast in the diagnosis of carotid artery occlusion

被引:40
作者
Ferrer, JME [1 ]
Samsó, JJ [1 ]
Serrano, JR [1 ]
Valenzuela, VF [1 ]
Montoya, SB [1 ]
Docampo, MM [1 ]
机构
[1] Hosp Gen Valle Hebron, Vasc Surg Staff, Barcelona 08006, Spain
关键词
D O I
10.1067/mva.2000.104599
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The purpose of this study was to evaluate the use of an echo-enhancing agent in patients with carotid artery occlusion to improve the sensitivity and specificity of carotid color flow ultrasonography Method: Between January 1997 and December 1998, a prospective study involving 85 cases of carotid artery occlusion in 84 patients was carried out. After a baseline duplex ultrasonography (DU) diagnosis, a second (DU) along with an echo-enhancement agent (SHU-508-A [Levovist]) study was carried out (echo enhancement ultrasonography diagnosis [DUEE]). In 82 cases, a contrast angiography was performed to confirm the diagnosis, whereas in the other three cases the diagnoses mere confirmed with surgery. Results: From the 85 internal carotid artery occlusions diagnosed at the initial DU examination, seven came out to be false occlusions in the DUEE examination (8,2%). There was a 100% correlation of the cases between the DUEE examination and the contrast angiography in the 82 cases in which this had been done. In three of the cases, the diagnosis was confirmed surgically because these displayed severe stenoses according to the DUEE studies in symptomatic patients, and so they required urgent treatment. Conclusions: The DUEE study is a potent diagnosis tool that allows the differentiation between hue carotid artery occlusions and pseudo-occlusions.
引用
收藏
页码:736 / 741
页数:6
相关论文
共 28 条
[1]   The reliability of color duplex ultrasound in diagnosing total carotid artery occlusion [J].
AbuRahma, AF ;
Pollack, JA ;
Robinson, PA ;
Mullins, D .
AMERICAN JOURNAL OF SURGERY, 1997, 174 (02) :185-187
[2]   Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion:: Preliminary experience [J].
Albrecht, T ;
Urbank, A ;
Mahler, M ;
Bauer, A ;
Doré, CJ ;
Blomley, MJK ;
Cosgrove, DO ;
Schlief, R .
RADIOLOGY, 1998, 207 (02) :339-347
[3]   CAROTID ENDARTERECTOMY WHEN THE DISTAL INTERNAL CAROTID-ARTERY IS SMALL OR POORLY VISUALIZED [J].
ARCHIE, JP .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (01) :23-31
[4]   DISTINGUISHING CAROTID-ARTERY PSEUDO-OCCLUSION WITH COLOR-FLOW DOPPLER [J].
BERMAN, SS ;
DEVINE, JJ ;
ERDOES, LS ;
HUNTER, GC .
STROKE, 1995, 26 (03) :434-438
[5]   THE LIMITATIONS OF DIAGNOSIS OF CAROTID OCCLUSION BY DOPPLER ULTRASOUND [J].
BORNSTEIN, NM ;
BELOEV, ZG ;
NORRIS, JW .
ANNALS OF SURGERY, 1988, 207 (03) :315-317
[6]   CLINICAL CORRELATES OF DOPPLER ULTRASOUND ERRORS IN THE DETECTION OF INTERNAL CAROTID-ARTERY OCCLUSION [J].
BRIDGERS, SL .
STROKE, 1989, 20 (05) :612-615
[7]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[8]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[9]   CAROTID-ARTERY IMAGING USING DUPLEX SCANNING AND BIDIRECTIONAL ARTERIOGRAPHY - A COMPARISON [J].
COLHOUN, E ;
MACERLEAN, D .
CLINICAL RADIOLOGY, 1984, 35 (02) :101-106
[10]   STENOSIS OF THE INTERNAL CAROTID-ARTERY - ASSESSMENT USING COLOR DOPPLER IMAGING COMPARED WITH ANGIOGRAPHY [J].
ERICKSON, SJ ;
MEWISSEN, MW ;
FOLEY, WD ;
LAWSON, TL ;
MIDDLETON, WD ;
QUIROZ, FA ;
MACRANDER, SJ ;
LIPCHIK, EO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) :1299-1305