Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis

被引:11
作者
Sano, Koichi
Mintz, Gary S.
Carlier, Stephane G. [1 ]
Fujii, Kenichi
Takebayashi, Hideo
Kimura, Masashi
Costa, Jose Ribamar, Jr.
Tanaka, Kaoru
Costa, Ricardo A.
Lui, Joanna
Weisz, Giora
Moussa, Issam
Dangas, George D.
Mehran, Roxana
Lansky, Alexandra J.
Kreps, Edward M.
Collins, Michael
Stone, Gregg W.
Moses, Jeffrey W.
Leon, Martin B.
机构
[1] Columbia Univ, Med Ctr, New York, NY USA
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
D O I
10.1016/j.amjcard.2006.07.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The neointimal hyperplasia (IH) distribution pattern of in-stent restenotic lesions after sirolimus-eluting stent (SES) implantation has not been well described. We identified 48 in-stent restenotic lesions (41 patients) after SES implantation and performed volumetric intravascular ultrasound analyses. Lumen area, stent area, and III area at the minimal lumen area site were 2.7 +/- 1.0, 5.4 +/- 1.9, and 2.7 +/- 1.4 mm(2), respectively. IH area at the minimal lumen site was larger in the group with a stent area >= 5.0 mm(2) than the group with a stent area < 5.0 mm(2) (3.7 +/- 1.3 vs 1.9 +/- 0.8 mm(2), P < 0.001). There were fewer visualized stent struts in lesions with a minimum stent area >= 5.0 mm(2) at the minimum lumen site compared with those with a stent area < 5.0 mm(2) (0.69 +/- 0.25 vs 0.83 +/- 0.16, p = 0.04). When we compared lesions in patients with diabetes mellitus with patients without diabetes, minimum lumen areas, percent IH at minimal lumen area, percent III, and neointima-free stent length were identical. In conclusion, (1) lesions without SES underexpansion at the minimum lumen site had more IH and greater nonuniform stent strut distribution compared with restenotic SESs that were underexpanded, and (2) the IH response did not appear to be more aggressive in patients with diabetes mellitus than in those without diabetes mellitus. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1559 / 1562
页数:4
相关论文
共 18 条
[1]   Strut position, blood flow, and drug deposition - Implications for single and overlapping drug-eluting stents [J].
Balakrishnan, B ;
Tzafriri, AR ;
Seifert, P ;
Groothuis, A ;
Rogers, C ;
Edelman, ER .
CIRCULATION, 2005, 111 (22) :2958-2965
[2]   Intravascular ultrasound stent area of sirolimus-eluting stents and its impact on late outcome [J].
Cheneau, E ;
Pichard, AD ;
Satler, LF ;
Suddath, WO ;
Weissman, NJ ;
Waksman, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (10) :1240-1242
[3]   Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis [J].
Halkin, A ;
Carlier, S ;
Leon, MB .
HEART, 2004, 90 (08) :e45
[4]   Impact of treatment of coronary artery disease with sirolimus-eluting stents on outcomes of diabetic and nondiabetic patients [J].
Kuchulakanti, PK ;
Torguson, R ;
Canos, D ;
Rha, SW ;
Chu, WW ;
Clavijo, L ;
Deible, R ;
Gevorkian, N ;
Suddath, WO ;
Satler, LF ;
Kent, KA ;
Pichard, AD ;
Waksman, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (08) :1100-1106
[5]   Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients - An evaluation from the Rapamycin-Eluting Stent evaluated at Rotterdam Cardiology Hospital (RESEARCH) study [J].
Lemos, PA ;
Hoye, A ;
Goedhart, D ;
Arampatzis, CA ;
Saia, F ;
van der Giessen, WJ ;
McFadden, E ;
Sianos, G ;
Smits, PC ;
Hofma, SH ;
de Feyter, PJ ;
van Domburg, RT ;
Serruys, PW .
CIRCULATION, 2004, 109 (11) :1366-1370
[6]   American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS) - A report of the American College of Cardiology Task Force on Clinical Expert Consensus - Documents developed in collaboration with the European Society of Cardiology endorsed by the Society of Cardiac Angiography and Interventions [J].
Mintz, GS ;
Nissen, SE ;
Anderson, WD ;
Bailey, SR ;
Erbel, R ;
Fitzgerald, PJ ;
Pinto, FJ ;
Rosenfield, K ;
Siegel, RJ ;
Tuzcu, EM ;
Yock, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1478-1492
[7]   A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. [J].
Morice, M ;
Serruys, PW ;
Sousa, JE ;
Fajadet, J ;
Hayashi, EB ;
Perin, M ;
Colombo, A ;
Schuler, G ;
Barragan, P ;
Guagliumi, G ;
Molnar, F ;
Falotico, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) :1773-1780
[8]   Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery [J].
Moses, JW ;
Leon, MB ;
Popma, JJ ;
Fitzgerald, PJ ;
Holmes, DR ;
O'Shaughnessy, C ;
Caputo, RP ;
Kereiakes, DJ ;
Williams, DO ;
Teirstein, PS ;
Jaeger, JL ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) :1315-1323
[9]   Impact of sirolimus-eluting stents on outcome in diabetic patients - A SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy [J].
Moussa, I ;
Leon, MB ;
Baim, DS ;
O'Neill, WW ;
Popma, JJ ;
Buchbinder, M ;
Midwall, J ;
Simonton, CA ;
Keim, E ;
Wang, P ;
Kuntz, RE ;
Moses, JW .
CIRCULATION, 2004, 109 (19) :2273-2278
[10]   Effect of sirolimus-eluting stent in diabetic patients with small coronary arteries (A SES-SMART substudy) [J].
Ortolani, P ;
Ardissino, D ;
Cavallini, C ;
Bramucci, E ;
Indolfi, C ;
Aquilina, M ;
Marzocchi, A .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (10) :1393-1398