Fabrication and characterization of nanostructured gold electrodes for electrochemical biosensors

被引:24
作者
Padeste, C [1 ]
Kossek, S [1 ]
Lehmann, HW [1 ]
Musil, CR [1 ]
Gobrecht, J [1 ]
Tiefenauer, L [1 ]
机构
[1] PAUL SCHERRER INST,CH-8048 ZURICH,SWITZERLAND
关键词
D O I
10.1149/1.1837312
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A process to structure gold electrodes with nanometer-sized dimensions for biosensor applications has been developed. Latex spheres (60 nm diam) are used as a masking material during the evaporation of a gold film onto a Si/SiO2 substrate. Openings left in the film after lift-off of the spheres are suitable in size to immobilize proteins such as antibodies or enzymes which can art as specific recognition elements. The nanometer-scale proximity of the recognition elements to the conducting material allows the development of mediatorless biosensors. This paper describes the optimization of the nanostructuring process as well as the morphological and electrochemical characterization of the structured electrodes.
引用
收藏
页码:3890 / 3895
页数:6
相关论文
共 16 条
  • [1] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [2] DICKS JM, 1989, ANN BIOL CLIN-PARIS, V47, P607
  • [3] ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS
    FOULDS, NC
    LOWE, CR
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1259 - 1264
  • [4] ELECTRON-TRANSFER BIOSENSORS
    FREW, JE
    HILL, HAO
    THOMAS, JDR
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) : 95 - 106
  • [5] GOSLING JP, 1990, CLIN CHEM, V36, P1408
  • [6] ELECTRICAL COMMUNICATION BETWEEN GLUCOSE-OXIDASE AND NOVEL FERROCENE-CONTAINING SILOXANE-ETHYLENE OXIDE COPOLYMERS - BIOSENSOR APPLICATIONS
    HALE, PD
    LEE, HS
    OKAMOTO, Y
    [J]. ANALYTICAL LETTERS, 1993, 26 (01) : 1 - 16
  • [7] POLYFERROCENES AS MEDIATORS IN AMPEROMETRIC BIOSENSORS FOR GLUCOSE
    HENDRY, SP
    CARDOSI, MF
    TURNER, APF
    NEUSE, EW
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 453 - 459
  • [8] AMPEROMETRIC DETERMINATION OF GLUCOSE WITH A FERROCENE-MEDIATED GLUCOSE-OXIDASE POLYACRYLAMIDE-GEL ELECTRODE
    LANGE, MA
    CHAMBERS, JQ
    [J]. ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) : 89 - 97
  • [9] Nanostructuring of gold electrodes for immunosensing applications
    Musil, CR
    Jeggle, D
    Lehmann, HW
    Scandella, L
    Gobrecht, J
    Dobeli, M
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1995, 13 (06): : 2781 - 2786
  • [10] MEDIATED GLUCOSE BIOSENSOR BASED ON POLYVINYLFERROCENE
    NGUYEN, AL
    LUONG, JHT
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1993, 43 (02) : 117 - 132