Determination of glycopeptide structures by multistage mass spectrometry with low-energy collision-induced dissociation: comparison of electrospray ionization quadrupole ion trap and matrix-assisted laser desorption/ionization quadrupole ion trap reflectron time-of-flight approaches

被引:77
作者
Demelbauer, UM
Zehl, M
Plematl, A
Allmaier, G
Rizzi, A
机构
[1] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Inst Chem Technol & Analyt, Vienna, Austria
关键词
D O I
10.1002/rcm.1521
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multistage mass spectrometry, as implemented using low-energy collision-induced dissociation (CID) analysis in three-dimensional (3D) quadrupole ion traps (QITs), has become a powerful tool for the investigation of protein glycosylation. In addition to the well-known combination of QITs with electrospray ionization (EST), also a matrix-assisted laser desorption/ionization --> quadrupole ion trap-reflectron time-of-flight (MALDI-QIT-rTOF) mass spectrometer has recently become available. This study systematically investigates the differences between these types of instrument, as applied to characterization of glycopeptides from human antithrombin. The glycopeptides were obtained by tryptic digestion followed by lectin-affinity purification. Some significant differences between the ESI-QIT and MALDI-QIT-rTOF approaches appeared, most of them are causally related to the desorption/ionization process. The combination of a vacuum MALDI source with an ion-trap analyzer accentuates some characteristic differences between MALDI and EST due the longer time frame needed for the trapping process. In contrast to EST, MALDI generated ions that exhibited considerable metastable fragmentation during trapping. The long time span of the QIT process (ms range) compared with that for conventional rTOF experiments (mus range) significantly magnified the extent of this metastable fragmentation. With the investigated glycopeptides, a complete depletion of the terminal sialic acids of the glycopeptides as well as a variety of other fragment ions was already found in the MS1 spectra from the MALDI-QIT-rTOF instrument. The positive ion low-energy CID spectra (MS2) of the selected glycopeptides obtained using the two different QIT equipped instruments were found to be quite similar. In both approaches, fragmentation of the glycan and peptide structures occurred sequentially, allowing unambiguous sequence determination. In the case of ESI-QIT-MS, fragmentation of the glycan structure occurred at the MS2 stage and fragmentation of the peptide structure was obtained only at the MS3 stage, which indicates the necessity of multistage CID experiments for complete structure elucidation. The MALDI-QIT-rTOF instrument yielded both kinds of fragments at the MS2 stage but without mutual interference. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1575 / 1582
页数:8
相关论文
共 30 条
  • [1] Cumming D. A., 1992, V76, P83
  • [2] DEMELBAUER U, 2004, UNPUB GLYCOBIOLOGY
  • [3] DEMELBAUER U, 2004, IN PRESS ELECTROPHOR
  • [4] High efficiency MALDI-QIT-ToF mass spectrometer
    Ding, L
    Kawatoh, E
    Tanaka, K
    Smith, AJ
    Kumashiro, S
    [J]. CHARGED PARTICLE OPTICS IV, 1999, 3777 : 144 - 155
  • [5] A SYSTEMATIC NOMENCLATURE FOR CARBOHYDRATE FRAGMENTATIONS IN FAB-MS MS SPECTRA OF GLYCOCONJUGATES
    DOMON, B
    COSTELLO, CE
    [J]. GLYCOCONJUGATE JOURNAL, 1988, 5 (04) : 397 - 409
  • [6] FRANZEN LE, 1980, J BIOL CHEM, V255, P5090
  • [7] Proteomics of glycoproteins based on affinity selection of glycopeptides from tryptic digests
    Geng, M
    Zhang, X
    Bina, M
    Regnier, F
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (02): : 293 - 306
  • [8] Gerwig GJ, 2000, EXS, V88, P159
  • [9] Harvey DJ, 2001, PROTEOMICS, V1, P311, DOI 10.1002/1615-9861(200102)1:2<311::AID-PROT311>3.0.CO
  • [10] 2-J