Dynamic flow alterations dictate leukocyte adhesion and response to endovascular interventions

被引:44
作者
Richter, Y
Groothuis, A
Seifert, P
Edelman, ER
机构
[1] Harvard Univ, MIT, Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[2] Brigham & Womens Hosp, Dept Med, Div Cardiovasc, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
D O I
10.1172/JCI200421007
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Although arterial bifurcations are frequent sites for obstructive atherosclerotic lesions, the optimal approach to these lesions remains unresolved. Benchtop models of arterial bifurcations were analyzed for flow disturbances known to correlate with vascular disease. These models possess an adaptable geometry capable of simulating the course of arterial disease and the effects of arterial interventions. Chronic in vivo studies evaluated the effect of flow disturbances on the pattern of neointimal hyperplasia. Acute in vivo studies helped propose a mechanism that bridges the early mechanical stimulus and the late tissue effect. Side-branch (SB) dilation adversely affected flow patterns in the main branch (MB) and, as a result, the long-term MB patency of stents implanted in pig arteries. Critical to this effect is chronic MB remodeling that seems to compensate for an occluded SB. Acute leukocyte recruitment was directly influenced by the changes in flow patterns, suggesting a link between flow disturbance on the one hand and leukocyte recruitment and intimal hyperplasia on the other. It is often impossible to simultaneously maximize the total cross-sectional area of both branches and to minimize flow disturbance in the MB. The apparent trade-off between these two clinically desirable goals may explain many of the common failure modes of bifurcation stenting.
引用
收藏
页码:1607 / 1614
页数:8
相关论文
共 41 条
[1]   Immediate and one-year outcome in patients with coronary bifurcation lesions in the modern era (NHLBI Dynamic Registry) [J].
Al Suwaidi, J ;
Yeh, WL ;
Cohen, HA ;
Detre, KM ;
Williams, DO ;
Holmes, DR .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (10) :1139-1144
[2]  
[Anonymous], CARDIOVASCULAR FLOW
[3]   FLOW PATTERNS AND SPATIAL-DISTRIBUTION OF ATHEROSCLEROTIC LESIONS IN HUMAN CORONARY-ARTERIES [J].
ASAKURA, T ;
KARINO, T .
CIRCULATION RESEARCH, 1990, 66 (04) :1045-1066
[4]  
Baim DS, 1996, CATHETER CARDIO DIAG, V37, P314, DOI 10.1002/(SICI)1097-0304(199603)37:3<314::AID-CCD22>3.0.CO
[5]  
2-G
[6]   STEADY FLOW IN A MODEL OF THE HUMAN CAROTID BIFURCATION .2. LASER-DOPPLER ANEMOMETER MEASUREMENTS [J].
BHARADVAJ, BK ;
MABON, RF ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1982, 15 (05) :363-378
[7]   STEADY FLOW IN A MODEL OF THE HUMAN CAROTID BIFURCATION .1. FLOW VISUALIZATION [J].
BHARADVAJ, BK ;
MABON, RF ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1982, 15 (05) :349-362
[8]  
Carlier SG, 1999, CATHETER CARDIO INTE, V47, P361, DOI 10.1002/(SICI)1522-726X(199907)47:3<361::AID-CCD26>3.3.CO
[9]  
2-5
[10]   Coronary stenting of bifurcation lesions using "T" or "reverse Y" configuration with Wiktor stent [J].
Carrié, D ;
Elbaz, M ;
Dambrin, G ;
Saint-Cricq, F ;
Dugrand, P ;
Fourcade, J ;
Puel, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (11) :1418-+