A cap-shaped device was employed for headspace sampling. This sampling device coupled to membrane extraction with a sorbent interface (MESI) is intended to perform on-site and on-line aqueous sample monitoring, A laboratory sampling test was performed both at the water surface and under water, and it showed some advantages in underwater monitoring. A group of volatile organic compounds (VOCs), varying in PDMS/gas and gas/water distribution constants, benzene, toluene, ethylbenzene, o-xylene, and trichloroethylene (TCE), was used for the sampling study. Magnetic stirring of the sample and circulation of the headspace air with a microfan were used for the enhancement of mass transfer between sample matrix and membrane to obtain higher extraction rate and efficiency. The agitation approaches were investigated individually and compared. The results showed that simultaneous agitation in water and air could greatly improve the extraction efficiency. Good linearity and precision and low detection limits were obtained for water-surface monitoring. The study demonstrated that Cap-MESI is a useful tool for field headspace monitoring of volatile organic compounds.
引用
收藏
页码:1058 / 1063
页数:6
相关论文
共 14 条
[1]  
Luo YZ, 1995, HRC-J HIGH RES CHROM, V18, P727
[2]   Calibration of membrane extraction for air analysis [J].
Luo, YZ ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :1064-1071
[3]   Aqueous sample direct extraction and analysis by membrane extraction with a sorbent interface [J].
Luo, YZ ;
Adams, M ;
Pawliszyn, J .
ANALYST, 1997, 122 (12) :1461-1469
[4]   Kinetic study of membrane extraction with a sorbent interface for air analysis [J].
Luo, YZ ;
Adams, M ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :248-254
[5]  
LUO YZ, 1999, THESIS U WATERLOO
[6]   Continuous monitoring of volatile organic compounds in air emissions using an on-line membrane extraction-microtrap-gas chromatographic system [J].
Mitra, S ;
Zhu, NH ;
Zhang, X ;
Kebbekus, B .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :165-173
[7]  
Mulder M., 2012, BASIC PRINCIPLES MEM
[8]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT
[9]   GAS EXTRACTION KINETICS OF VOLATILE ORGANIC-SPECIES FROM WATER WITH A HOLLOW FIBER MEMBRANE [J].
PRATT, KF ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2101-2106
[10]   WATER MONITORING-SYSTEM BASED ON GAS EXTRACTION WITH A SINGLE HOLLOW FIBER MEMBRANE AND GAS-CHROMATOGRAPHIC CRYOTRAPPING [J].
PRATT, KF ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2107-2110