Comparison of x-ray cross sections for diagnostic and therapeutic medical physics

被引:163
作者
Boone, JM
Chavez, AE
机构
[1] Department of Radiology, UC Davis Medical Center, FOLB II E, Sacramento, CA 95817
关键词
cross section; attenuation coefficient; national laboratory; atomic data;
D O I
10.1118/1.597899
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this technical report is to make available an up-to-date source of attenuation coefficient data to the medical physics community, and to compare these data with other more familiar sources. Data files from Lawrence Livermore National Laboratory (in Livermore, CA) were truncated to match the needs of the medical physics community, and an interpolation routine was written to calculate a continuous set of cross sections spanning energies from 1 keV to 50 MeV. Coefficient data are available for elements Z = 1 through Z = 100. Values for mass attenuation coefficients, mass-energy-transfer coefficients, and mass-energy absorption coefficients are produced by a single computer subroutine. In addition to total interaction cross sections, the cross sections for the photoelectric, Rayleigh, Compton, pair, and some triplet interactions are also produced by this single program. The coefficients were compared to the 1970 data of Storm and Israel over the energy interval from 1 to 1000 keV; for elements 10, 20, 30, 40, 50, 60, 70, and 80, the average positive difference between the Storm and Israel coefficients and the coefficients reported here are 1.4%, 2.7%, and 2.6%, for the mass attenuation, mass energy-transfer, and mass-energy absorption coefficients, respectively. The 1969 data compilation of mass attenuation coefficients from McMaster et al. were also compared with the newer LLNL data. Over the energy region from 10 keV to 1000 keV, and from elements Z = 1 to Z = 82 (inclusive), the overall average difference was 1.53% (sigma = 0.85%). While the overall average difference was small, there was larger variation (> 5%) between cross sections for some elements. In addition to coefficient data, other useful data such as the density, atomic weight, K,L(1),L(2),L(3),M, and N edges, and numerous characteristic emission energies are output by the program, depending on a single input variable. The computer source code, written in C, can be accessed and downloaded from the World Wide Web at: http://www.aip.org/epaps/epaps.html [E-MPHSA-23-1997] (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1997 / 2005
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 1986, 863431 NBSIR
[2]  
Berger M. J., 1987, 873597 NBSIR
[3]   PARAMETRIZED X-RAY ABSORPTION IN DIAGNOSTIC-RADIOLOGY FROM MONTE-CARLO CALCULATIONS - IMPLICATIONS FOR X-RAY-DETECTOR DESIGN [J].
BOONE, JM .
MEDICAL PHYSICS, 1992, 19 (06) :1467-1473
[4]   MONTE-CARLO SIMULATION OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :713-720
[5]   THE VALIDITY OF MONTE-CARLO SIMULATION IN STUDIES OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY [J].
CHAN, HP ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) :109-129
[6]   INVESTIGATION OF ENERGY RESPONSES OF GERMANIUM DETECTORS AND CORRECTION OF MEASURED SPECTRA BY MEANS OF MONTE-CARLO SIMULATION [J].
CHAN, HP ;
CHEN, CT ;
DOI, K ;
FEWELL, TR ;
SHUPING, RE .
RADIATION RESEARCH, 1984, 99 (03) :443-464
[7]   PHYSICAL CHARACTERISTICS OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY - MONTE-CARLO SIMULATION STUDIES [J].
CHAN, HP ;
DOI, K .
MEDICAL PHYSICS, 1985, 12 (02) :152-165
[8]   RADIATION-DOSE IN DIAGNOSTIC-RADIOLOGY - MONTE-CARLO SIMULATION STUDIES [J].
CHAN, HP ;
DOI, K .
MEDICAL PHYSICS, 1984, 11 (04) :480-490
[9]   STUDIES OF X-RAY-ENERGY ABSORPTION AND QUANTUM NOISE PROPERTIES OF X-RAY SCREENS BY USE OF MONTE-CARLO SIMULATION [J].
CHAN, HP ;
DOI, K .
MEDICAL PHYSICS, 1984, 11 (01) :37-46
[10]   MONTE-CARLO SIMULATION STUDIES OF DETECTORS USED IN THE MEASUREMENT OF DIAGNOSTIC-X-RAY SPECTRA [J].
CHEN, CS ;
DOI, K ;
VYBORNY, C ;
CHAN, HP ;
HOLJE, G .
MEDICAL PHYSICS, 1980, 7 (06) :627-635