Effects of storage conditions on chemical and physical properties of electrolyzed oxidizing water

被引:48
作者
Hsu, SY [1 ]
Kao, HY [1 ]
机构
[1] Natl Taiwan Univ, Grad Inst Food Sci & Technol, Taipei 106, Taiwan
关键词
electrolyzed oxidizing water; storage; total residual chlorine; dissolved oxygen;
D O I
10.1016/j.jfoodeng.2004.02.009
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Electrolyzed oxidizing waters (EOWs) were generated at different water flow rates, salt concentrations and water temperatures. The EOWs were stored in closed dark-brown glass bottles at room temperature for 21 days. Another duplicated set of the EOWs were stored for 12 days with four periodical openings of the screw caps. The effects of these treatments on pH, oxidation-reduction potential (ORP), electrical conductivity, total residual chlorine, dissolved oxygen (DO), sodium ion and chloride ion concentrations of the EOWs were investigated. Results indicated that pH, ORP, conductivity and chloride ion concentration did not change much under the storage conditions. Sodium ion concentration decreased 10-13% during storage. Total residual chlorine and DO decreased 24% and 21%, respectively, in the 21-day closed storage and decreased 81% and 47%, respectively, in the 12-day semi-open storage. This indicated that exposure to the atmosphere reduced more of these compounds than prolongation of the storage time. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 22 条
[1]   Disinfection effects of electrolyzed oxidizing water on suppressing fruit rot of pear caused by Botryosphaeria berengeriana [J].
Al-Haq, MI ;
Seo, Y ;
Oshita, S ;
Kawagoe, Y .
FOOD RESEARCH INTERNATIONAL, 2002, 35 (07) :657-664
[2]   Fungicidal effectiveness of electrolyzed oxidizing water on postharvest brown rot of peach [J].
Al-Haq, MI ;
Seo, Y ;
Oshita, S ;
Kawagoe, Y .
HORTSCIENCE, 2001, 36 (07) :1310-1314
[3]  
*AM PUBL HLTH ASS, 1975, STAND METH EX WAT WA, P316
[4]   In vitro fungicidal activity of acidic electrolyzed oxidizing water [J].
Buck, JW ;
van Iersel, MW ;
Oetting, RD ;
Hung, YC .
PLANT DISEASE, 2002, 86 (03) :278-281
[5]   Comparison of electrolyzed oxidizing water with various antimicrobial interventions to reduce Salmonella species on poultry [J].
Fabrizio, KA ;
Sharma, RR ;
Demirci, A ;
Cutter, CN .
POULTRY SCIENCE, 2002, 81 (10) :1598-1605
[6]   Bactericidal effect of electrolyzed neutral water on bacteria isolated from infected root canals [J].
Horiba, N ;
Hiratsuka, K ;
Onoe, T ;
Yoshida, T ;
Suzuki, K ;
Matsumoto, T ;
Nakamura, H .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 87 (01) :83-87
[7]   Effects of water flow rate, salt concentration and water temperature on efficiency of an electrolyzed oxidizing water generator [J].
Hsu, SY .
JOURNAL OF FOOD ENGINEERING, 2003, 60 (04) :469-473
[8]  
HSU SY, IN PRESS J FOOD ENG
[9]   Electrolyzed water as a disinfectant for fresh-cut vegetables [J].
Izumi, H .
JOURNAL OF FOOD SCIENCE, 1999, 64 (03) :536-539
[10]  
JOGLEKAR AM, 1987, CEREAL FOOD WORLD, V32, P857