Does refractive error influence the association of blood pressure and retinal vessel diameters? The blue mountains eye study

被引:69
作者
Wong, TY
Wang, JJ
Rochtchina, E
Klein, R
Mitchell, P
机构
[1] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
[2] Natl Univ Singapore, Singapore Eye Res Inst, Singapore 117548, Singapore
[3] Univ Sydney, Ctr Vis Res, Dept Ophthalmol, Westmead, NSW 2145, Australia
[4] Univ Wisconsin, Dept Ophthalmol, Madison, WI USA
关键词
D O I
10.1016/j.ajo.2004.01.035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine if refractive errors influence the association of blood pressure and retinal vessel diameters. DESIGN: Population based, cross-sectional study. METHODS: Retinal photographs from the right eyes of participants (n = 3,654, aged 49+ years) in the Blue Mountains Eye Study taken during baseline examinations (1992 to 1994) were digitized. The diameter of all retinal vessels located half to one disk diameter from the disk margin was measured using a computer,assisted imaging program. These measurements were combined to provide the average diameters of retinal arterioles and venules of that eye, and the ratio of their diameters, the arteriole-to-venule ratio (AVR). The association of blood pressure and retinal vessel diameters was analyzed before and after correction for refraction using the Bengtsson formula. RESULTS: Before correction, each 10-mm, Hg increase in mean arterial blood pressure was associated with a 3.7-mum (95% confidence interval [CI], 3.2-4.3) decrease in arteriolar diameter and a 0.9-mum (95% CI, 0.3-0.9) decrease in venular diameter. After correction for refraction, each 1-mm Hg increase in mean arterial blood pressure was associated with a 3.7-mum (95% CI, 3.2-4.2) decrease in arteriolar diameter and a 0.8-mum (95% CI, 0.3-0.9) decrease in venular diameter. Refraction was not associated with the AVR and had no effect on the association of blood pressure and AVR. CONCLUSION: Refraction had no appreciable effect on the association of blood pressure and retinal vessel diameters or on the AVR. Correction for refraction is important for quantifying absolute retinal vessel caliber, but may not be particularly important in epidemiologic studies investigating the association of generalized retinal arteriolar narrowing and hypertension. (C) 2004 by Elsevier Inc. All rights reserved.
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 26 条
[1]  
[Anonymous], J AM STAT ASSOC
[2]  
ARNOLD JV, 1993, INVEST OPHTH VIS SCI, V34, P2576
[3]  
Attebo K, 1996, OPHTHALMOLOGY, V103, P357
[4]   Refractive errors in an older population - The blue mountains eye study [J].
Attebo, K ;
Ivers, RQ ;
Mitchell, P .
OPHTHALMOLOGY, 1999, 106 (06) :1066-1072
[5]  
BENGTSSON B, 1976, ACTA OPHTHALMOL, V54, P804
[6]   CORRECTION OF OPTIC DISK MEASUREMENTS ON FUNDUS PHOTOGRAPHS [J].
BENGTSSON, B ;
KRAKAU, CET .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (01) :24-28
[7]   Reliability of retinal photography in the assessment of retinal microvascular characteristics: The atherosclerosis risk in communities study [J].
Couper, DJ ;
Klein, R ;
Hubbard, LD ;
Wong, TY ;
Sorlie, PD ;
Cooper, LS ;
Brothers, RJ ;
Nieto, FJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (01) :78-88
[8]   Optic disk size in open-angle glaucoma: The Blue Mountains Eye Study [J].
Healey, PR ;
Mitchell, P .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (04) :515-517
[9]  
HEIER H, 1989, INVEST OPHTH VIS SCI, V30, P674
[10]  
Houben AJHM, 1995, J HYPERTENS, V13, P1729