Determining CDOM absorption spectra in diverse coastal environments using a multiple pathlength, liquid core waveguide system

被引:79
作者
Miller, RL
Belz, M
Del Castillo, C
Trzaska, R
机构
[1] NASA, Stennis Space Ctr, MS 39529 USA
[2] World Precis Instruments Inc, Sarasota, FL 34240 USA
[3] GB Tech, Stennis Space Ctr, MS 39529 USA
基金
美国国家航空航天局;
关键词
absorption; absorbance; coastal optics; CDOM; liquid core waveguide; spectrophotometers;
D O I
10.1016/S0278-4343(02)00009-2
中图分类号
P7 [海洋学];
学科分类号
0707 ;
摘要
We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(CDOM) for MPLCW measurements was 0.002-231.5 m(-1). At low CDOM concentrations (a(370) < 0.1 m(-1)) spectrophotometric a(CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was <0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1301 / 1310
页数:10
相关论文
共 25 条
[1]  
AAS E, 2001, P OC OPT MON, V15
[2]   Impact of chromophoric dissolved organic matter on UV inhibition of primary productivity in the sea [J].
Arrigo, KR ;
Brown, CW .
MARINE ECOLOGY PROGRESS SERIES, 1996, 140 (1-3) :207-216
[3]   Liquid core waveguide with fiber optic coupling for remote pollution monitoring in the deep ultraviolet [J].
Belz, M ;
Dress, P ;
Klein, KF ;
Boyle, WJO ;
Franke, H ;
Grattan, KTV .
WATER SCIENCE AND TECHNOLOGY, 1998, 37 (12) :279-284
[4]   Linearity and effective optical pathlength of liquid waveguide capillary cells. [J].
Belz, M ;
Dress, P ;
Sukhitskiy, A ;
Liu, S .
INTERNAL STANDARDIZATION AND CALIBRATION ARCHITECTURES FOR CHEMICAL SENSORS, 1999, 3856 :271-281
[5]  
BRICAUD A, 1981, LIMNOL OCEANOGR, V26, P43
[6]  
Byrne R, 1999, SEA TECHNOL, V40, P71
[7]   Use of liquid core waveguides for long pathlength absorbance spectroscopy: Principles and practice - Comment [J].
Byrne, RH ;
Kaltenbacher, E .
LIMNOLOGY AND OCEANOGRAPHY, 2001, 46 (03) :740-742
[8]   REFLECTANCE MODEL FOR QUANTIFYING CHLOROPHYLL-A IN THE PRESENCE OF PRODUCTIVITY DEGRADATION PRODUCTS [J].
CARDER, KL ;
HAWES, SK ;
BAKER, KA ;
SMITH, RC ;
STEWARD, RG ;
MITCHELL, BG .
JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1991, 96 (C11) :20599-20611
[9]   MARINE HUMIC AND FULVIC-ACIDS - THEIR EFFECTS ON REMOTE-SENSING OF OCEAN CHLOROPHYLL [J].
CARDER, KL ;
STEWARD, RG ;
HARVEY, GR ;
ORTNER, PB .
LIMNOLOGY AND OCEANOGRAPHY, 1989, 34 (01) :68-81
[10]  
COBLE PG, 2000, P OC OPT MON, V15