Quantitation of Chemical Warfare Agents Using the Direct Analysis in Real Time (DART) Technique

被引:138
作者
Nilles, J. Michael [1 ]
Connell, Theresa R. [1 ]
Durst, H. Dupont [2 ]
机构
[1] Excet Inc, Springfield, VA 22151 USA
[2] Edgewood Chem Biol Ctr, Aberdeen Proving Ground, Edgewood, MD 21040 USA
关键词
MASS-SPECTROMETRY; RAPID ANALYSIS; ION-SOURCE; OF-FLIGHT; QUANTIFICATION; DRUGS;
D O I
10.1021/ac900682f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct analysis in real time (DART) is an ion source that pen-nits rapid mass spectrometric detection of gases, liquids, and solids in open air under ambient conditions. It is a unique technology in the field of chemical weapons detectors in that it does not require a vapor pressure, does not require sample preparation, and is nondestructive to the original sample. While the DART technique has had success as a first line instrument of detection, there have been lingering doubts over the technique's quantitative reliability and reproducibility. Here, we demonstrate its capability to produce linear calibration curves (R-2 = 0.99 or better) for the nerve agents GA, GB, and VX as well as the blister agent HID. Independently prepared check standards measured against these curves typically have recovery errors less than 3%. We show the DART instrument response to be linear over roughly 3 orders of magnitude. Furthermore, this study shows that averaging as few as three measurements for each data point is sufficient to produce high quality calibration curves, thus reducing data collection time and providing quicker results.
引用
收藏
页码:6744 / 6749
页数:6
相关论文
共 30 条
[1]  
BENNETT MJ, J FORENSIC IN PRESS
[2]  
Cajka T, 2008, LC GC EUR, V21, P250
[3]  
CAJKA TV, 2008, J ORGANOHALOGEN COMP, V70, P922
[4]  
COATES CM, 2008, FORENSIC IDENTIFICAT, V58, P624
[5]  
Cody R.B., 2005, JEOL News, V40, P8, DOI DOI 10.1021/AC050162J
[6]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[7]   Observation of Molecular Ions and Analysis of Nonpolar Compounds with the Direct Analysis in Real Time Ion Source [J].
Cody, Robert B. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1101-1107
[8]   Prevalence and detection of counterfeit pharmaceuticals: A mini review [J].
Fernandez, Facundo M. ;
Green, Michael D. ;
Newton, Paul N. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (03) :585-590
[9]   Characterization of solid counterfeit drug samples by desorption electrospray ionization and direct-analysis-in-real-time coupled to time-of-flight mass spectrometry [J].
Fernandez, Facundo M. ;
Cody, Robert B. ;
Green, Michael D. ;
Hampton, Christina Y. ;
McGready, Rose ;
Sengaloundeth, Sivong ;
White, Nicholas J. ;
Newton, Paul N. .
CHEMMEDCHEM, 2006, 1 (07) :702-+
[10]   Direct mass spectrometric analysis of flavors and fragrances in real applications using DART [J].
Haefliger, Olivier P. ;
Jeckelmann, Nicolas .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (08) :1361-1366