Parallel RF transmission in MRI

被引:173
作者
Katscher, U [1 ]
Börnert, P [1 ]
机构
[1] Philips Res Labs, D-22335 Hamburg, Germany
关键词
parallel transmission; transmit SENSE; parallel excitation; spatially selective RF pulses; multidimensional RF pulses; RF coil array design; SAR; parallel imaging;
D O I
10.1002/nbm.1049
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Following the development of parallel imaging, parallel transmission describes the use of multiple RF transmit coils. Parallel transmission can be applied to improve RF excitation, in particular, multidimensional, spatially selective RF excitation. For instance, parallel transmission is able to shorten spatially selective RF pulses in two or three dimensions, or to minimize the occurring SAR. One potential major application might be the compensation of patient-induced B, inhomogeneities, particularly at high main fields. This paper provides an overview of selected aspects of this new transmission approach. The basic principles of parallel transmission are discussed, initial experimental proofs are described, and the impact of error propagation on coil design for parallel transmission is outlined. Copyright (C) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 45 条
[1]
Transmit and receive transmission line arrays for 7 tesla parallel imaging [J].
Adriany, G ;
Van de Moortele, PF ;
Wiesinger, F ;
Moeller, S ;
Strupp, JP ;
Andersen, P ;
Snyder, C ;
Zhang, XL ;
Chen, W ;
Pruessmann, KP ;
Boesiger, P ;
Vaughan, T ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :434-445
[2]
A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI [J].
Barker, GJ ;
Simmons, A ;
Arridge, SR ;
Tofts, PS .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :59-67
[3]
Börnert P, 1998, MAGN RESON MATER PHY, V7, P166
[4]
Curved slice imaging [J].
Bornert, P ;
Schaffter, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :932-939
[5]
BOSKAMP E, 2002, P INT SOC MAGN RESON, V10, P903
[6]
PROGRESS IN EFFICIENT 3-DIMENSIONAL SPATIALLY LOCALIZED INVIVO P-31 NMR-SPECTROSCOPY USING MULTIDIMENSIONAL SPATIALLY SELECTIVE (RHO) PULSES [J].
BOTTOMLEY, PA ;
HARDY, CJ .
JOURNAL OF MAGNETIC RESONANCE, 1987, 74 (03) :550-556
[7]
CARLSEN IC, 1994, P SOC MAGN RESON, V2, P834
[8]
AN ALGORITHM FOR NMR IMAGING RECONSTRUCTION BASED ON MULTIPLE RF RECEIVER COILS [J].
CARLSON, JW .
JOURNAL OF MAGNETIC RESONANCE, 1987, 74 (02) :376-380
[9]
VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[10]
COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270