Polyelectrolyte electrophoresis in a dilute solution of neutral polymers: Model studies

被引:26
作者
Starkweather, ME
Hoagland, DA [1 ]
Muthukumar, M
机构
[1] Univ Massachusetts, Dept Polymer Sci & Engn, Amherst, MA 01003 USA
[2] Univ Massachusetts, Mat Res Sci & Engn Ctr, Amherst, MA 01003 USA
关键词
D O I
10.1021/ma9911546
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Dilute neutral polymer solutions provide an effective environment for the electrophoretic separation of polyelectrolytes by molecular weight. To better understand the mechanisms responsible, this study examines how the molecular weight dependent mobility mu of poly(styrenesulfonate), termed the probe chain, depends on the molecular weight and concentration of various dilute pullulans, termed the host chains. Available for this system are nearly monodisperse probes and hosts. Carefully performed capillary electrophoresis experiments measure absolute values of mu and its distribution. Below the overlap concentration, hosts reduce mu from its free solution value in proportion to concentration. The strongest dependence of mu on probe molecular weight occurs at nearly equal probe and host chain lengths. The influence of host and probe chain lengths on mu can be understood in terms of pairwise probe-host configurational interactions. Three parameters-entanglement probability, average entanglement duration, and average entanglement displacement-capture the interaction dynamics and help to explain observed variations in mu.
引用
收藏
页码:1245 / 1253
页数:9
相关论文
共 39 条
[1]   HIGH-RESOLUTION SEPARATION OF DNA RESTRICTION FRAGMENTS BY CAPILLARY ELECTROPHORESIS IN CELLULOSE DERIVATIVE SOLUTIONS [J].
BABA, Y ;
ISHIMARU, N ;
SAMATA, K ;
TSUHAKO, M .
JOURNAL OF CHROMATOGRAPHY A, 1993, 653 (02) :329-335
[2]   THE USE OF COATED AND UNCOATED CAPILLARIES FOR THE ELECTROPHORETIC SEPARATION OF DNA IN DILUTE POLYMER-SOLUTIONS [J].
BARRON, AE ;
SUNADA, WM ;
BLANCH, HW .
ELECTROPHORESIS, 1995, 16 (01) :64-74
[3]   CAPILLARY ELECTROPHORESIS OF DNA IN UNCROSS-LINKED POLYMER-SOLUTIONS [J].
BARRON, AE ;
SOANE, DS ;
BLANCH, HW .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :3-16
[4]   A TRANSIENT ENTANGLEMENT COUPLING MECHANISM FOR DNA SEPARATION BY CAPILLARY ELECTROPHORESIS IN ULTRADILUTE POLYMER-SOLUTIONS [J].
BARRON, AE ;
BLANCH, HW ;
SOANE, DS .
ELECTROPHORESIS, 1994, 15 (05) :597-615
[5]  
Barron AE, 1996, BIOTECHNOL BIOENG, V52, P259, DOI 10.1002/(SICI)1097-0290(19961020)52:2<259::AID-BIT7>3.3.CO
[6]  
2-#
[8]   USE OF LIQUID POLYACRYLAMIDE IN ELECTROPHORESIS .3. PROPERTIES OF LIQUID POLYACRYLAMIDE IN THE PRESENCE OF CELLULOSE-ACETATE [J].
BODE, HJ .
ANALYTICAL BIOCHEMISTRY, 1979, 92 (01) :99-110
[9]   Capillary electrophoretic separation of DNA restriction fragments in mixtures of low- and high-molecular-weight hydroxyethylcellulose [J].
Bunz, AP ;
Barron, AE ;
Prausnitz, JM ;
Blanch, HW .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (09) :2900-2908
[10]   DANCING DNA IN CAPILLARY SOLUTION ELECTROPHORESIS [J].
CARLSSON, C ;
LARSSON, A ;
JONSSON, M ;
NORDEN, B .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (13) :3871-3872