Systematic procedures for sizing photovoltaic pumping system, using water tank storage

被引:68
作者
Hamidat, A. [1 ]
Benyoucef, B. [2 ]
机构
[1] Renewable Energies Dev Ctr, Algiers, Algeria
[2] Univ Tlemcen, Lab Mat & Renewable Energies, Tilimsen, Algeria
关键词
Photovoltaic pumping; Load losses probability; Motor-pump; BRUSHLESS DC MOTOR; VARIABLE DEMAND; ENERGY; MODEL; PERFORMANCE; IRRIGATION; SIMULATION; ALGERIA; INDIA;
D O I
10.1016/j.enpol.2008.12.014
中图分类号
F [经济];
学科分类号
02 ;
摘要
In this work, the performances of the photovoltaic pumping destined to supply drinking water in remote and scattered small villages have been studied. The methodology adopted proposes various procedures based on the water consumption profiles, total head, tank capacity and photovoltaic array peak power. A method of the load losses probability (LLP) has been used to optimize sizing of the photovoltaic Pumping systems with a similarity between the storage energy in batteries and water in tanks. The results were carried out using measured meteorological data for four localities in Algeria: Algiers and Oran in the north, Bechar and Tamanrasset in the south. The results show that the performance of the photovoltaic pumping system depends deeply on the pumping total head and the peak power of the photovoltaic array. Also, for the southern localities, the LLP method shows that the size of the photovoltaic array varies versus LLP on a small scale. On the other hand, for the northern localities, the sizing of the photovoltaic array is situated on a large scale power. Because of the current high crud-oil price, the photovoltaic pumping still to be the best adopted energy resource to supply drinking water in remote and scattered villages. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1489 / 1501
页数:13
相关论文
共 33 条
[1]   Matching of separately excited dc motors to photovoltaic generators for maximum power output [J].
Akbaba, M ;
Qamber, I ;
Kamal, A .
SOLAR ENERGY, 1998, 63 (06) :375-385
[2]  
Al-Karaghouli Ali, 2007, CURRENT STATUS RENEW
[3]  
[Anonymous], 2006, World Energy Outlook 2006, Summary and Conclusions
[4]   Time dependent model of a complex PV water pumping system [J].
Badescu, V .
RENEWABLE ENERGY, 2003, 28 (04) :543-560
[5]   Evaluation of technical improvements of photovoltaic systems through life cycle assessment methodology [J].
Battisti, R ;
Corrado, A .
ENERGY, 2005, 30 (07) :952-967
[6]  
BOUDGHENE SA, 2006, C NAT EN SOL CNESOL, P93
[7]   Effect of different load profiles on the loss-of-load probability of stand-alone photovoltaic systems [J].
Celik, A. N. .
RENEWABLE ENERGY, 2007, 32 (12) :2096-2115
[8]   A COMPARATIVE-STUDY OF EXTRACTION METHODS FOR SOLAR-CELL MODEL PARAMETERS [J].
CHAN, DSH ;
PHILLIPS, JR ;
PHANG, JCH .
SOLID-STATE ELECTRONICS, 1986, 29 (03) :329-337
[9]   Solar powered induction motor-driven water pump operating on a desert well, simulation and field tests [J].
Daud, AK ;
Mahmoud, MM .
RENEWABLE ENERGY, 2005, 30 (05) :701-714
[10]   An efficient algorithm to simulate the electrical performance of solar photovoltaic arrays [J].
Gautam, NK ;
Kaushika, ND .
ENERGY, 2002, 27 (04) :347-361