Thermal and mechanical analysis of a microreactor for high temperature catalytic gas phase reactions

被引:30
作者
Tiggelaar, RM
Loeters, PWH
van Male, P
Oosterbroek, RE
Gardeniers, JGE
de Croon, MHJM
Schouten, JC
Elwenspoek, MC
van den Berg, A
机构
[1] Univ Twente, Transducers Sci & Technol Grp, MESA Res Inst, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, Lab Thermal Engn, MESA Res Inst, NL-7500 AE Enschede, Netherlands
[3] Univ Twente, Lab Biosensors, MESA Res Inst, NL-7500 AE Enschede, Netherlands
[4] Eindhoven Univ Technol, Lab Chem Reactor Engn, NL-5600 MB Eindhoven, Netherlands
关键词
microreactor; lab-on-a-chip; thermal analysis; thermo-mechanical analysis; modeling;
D O I
10.1016/j.sna.2004.01.036
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this contribution we describe the results of a study into the thermal and thermo-mechanical behavior of a high temperature micro gas reactor for investigation of the intrinsic reaction kinetics of rhodium-catalyzed direct catalytic partial oxidation (CPO) of methane into synthesis gas. The chip comprises a flow channel etched in silicon, capped with a thin composite membrane of heavily boron-doped silicon (p(++)-Si) and low stress silicon-rich nitride (SiRN), on which thin film heaters and sensors are located. The results of analytical and numerical models, which are verified with experimental results, can be used as general guidelines for the design of membrane-based microreactors. It is found that a membrane composition of 850 nm p(++)-Si and 150 nm SiRN result in time constants of I ms for heating up as well as cooling down, which enables the required fast control of the exothermic reaction. Thermo-mechanical analyses demonstrated that this membrane is mechanically stable for temperatures up to at least 700degreesC. Although the shape of the heaters-meander or sinusoidal-does not influence the mechanical stress profiles significantly, a decrease in heater width compared to the membrane width results in a drastically improved thermal efficiency of the microreactor. Furthermore, thermal considerations showed that exact temperature distribution in the composite membrane is mainly determined by the heater width in combination with the thickness of the heavily boron-doped silicon part of the membrane and its (temperature-dependent) thermal conductivity. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 277
页数:11
相关论文
共 21 条
[1]   Microsystem for high-temperature gas phase reactions [J].
Alépée, C ;
Vulpescu, L ;
Cousseau, P ;
Renaud, P ;
Maurer, R ;
Renken, A .
MEASUREMENT & CONTROL, 2000, 33 (09) :265-268
[2]  
ALEPEE C, 1999, P 3 INT C MICR TECHN, P514
[3]   Thermal conduction in doped single-crystal silicon films [J].
Asheghi, M ;
Kurabayashi, K ;
Kasnavi, R ;
Goodson, KE .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (08) :5079-5088
[4]  
Bassous E., 1989, Microelectronic Engineering, V9, P167, DOI 10.1016/0167-9317(89)90039-7
[5]  
Bejan A., 1993, Heat Transfer
[6]  
DESMET CRH, 2000, THESIS EINDHOVEN U T
[7]  
DING X, 1990, SENSOR ACTUAT A-PHYS, V21, P866
[8]  
Ehrfeld W., 2000, Microreactors: new technology for modern chemistry, DOI DOI 10.1002/3527601953
[9]   LPCVD silicon-rich silicon nitride films for applications in micromechanics, studied with statistical experimental design [J].
Gardeniers, JGE ;
Tilmans, HAC ;
Visser, CCG .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 1996, 14 (05) :2879-2892
[10]  
Gere J., 1987, MECH MAT