Surface heparinization of central venous catheters reduces microbial colonization in vitro and in vivo: Results from a prospective, randomized trial

被引:99
作者
Appelgren, P
RansjO, U
Bindslev, L
Espersen, F
Larm, O
机构
[1] KAROLINSKA HOSP,DEPT CLIN MICROBIOL,S-10401 STOCKHOLM,SWEDEN
[2] KAROLINSKA HOSP,DEPT ANESTHESIOL,S-10401 STOCKHOLM,SWEDEN
[3] STATE SERUM INST,DIV PREVENT MICROBIOL,COPENHAGEN,DENMARK
[4] MEDICARB AB,BROMMA,SWEDEN
关键词
central venous catheters; microbial colonization; sepsis; bacterial infection; nosocomial infection; heparin;
D O I
10.1097/00003246-199609000-00009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate in vitro and in vivo the efficacy of covalent end point-attached heparin to single-lumen polyurethane central venous catheters in reducing microbial adherence and colonization. Design: In vitro study: A controlled bench study. In vivo study: A prospective, randomized, double-blind, clinical trial. Setting: Intensive care unit in a 1200-bed teaching hospital, Interventions: In vitro study: Adhesion of 17 radiolabeled clinical isolates of Staphylococci to catheters was examined in vitro. In vivo study: The outcome of heparinized and control catheters was compared in vivo in patients receiving long term parenteral nutrition, Fifty-five adult patients were prospectively, blindly randomized to heparinized or control central venous catheters, The catheters, removed on clinical grounds, were analyzed with semiquantitative and quantitative cultures. Blood cultures were done at catheter removal. Measurements and Main Results: In vitro study: Coagulase-negative Staphylococci adhered less in vitro to heparinizedcatheters than to control catheters (p <.05). In vivo study: Among 32 central venous catheters, or patients who completed the study, catheter associated bacteremia or fungemia was observed in five patients in the control group (n = 19) and in no patient with a heparinized catheter (n = 13) (p = .047), Four of 13 catheters in the heparin group were colonized compared with 14 of 19 in the control group (p = .03). Coagulase-negative Staphylococci were the most frequent microorganisms in both groups. The numbers of organisms found on colonized catheters were larger in the control group than in the heparin group. Conclusions: Covalent end point surface heparinization appears to have a great impact on both in vitro and in vivo bacterial colonization of central venous catheters, Such heparinization can be a practical and economical approach to the prevention of catheter-associated bacteremia or fungemia.
引用
收藏
页码:1482 / 1489
页数:8
相关论文
共 45 条
[1]  
AOYAMA T, 1987, CHEM PHARM BULL, V35, P808
[2]   LONG-TERM STABILITY INVIVO OF A THROMBORESISTANT HEPARINIZED SURFACE [J].
ARNANDER, C ;
BAGGERSJOBACK, D ;
FREBELIUS, S ;
LARSSON, R ;
SWEDENBORG, J .
BIOMATERIALS, 1987, 8 (06) :496-499
[3]   ROUTINE SEMIQUANTITATIVE CULTURES AND CENTRAL VENOUS CATHETER-RELATED BACTEREMIA [J].
AUFWERBER, E ;
RINGERTZ, S ;
RANSJO, U .
APMIS, 1991, 99 (07) :627-630
[4]   REDUCTION OF CATHETER-ASSOCIATED SEPSIS IN PARENTERAL-NUTRITION USING LOW-DOSE INTRAVENOUS HEPARIN [J].
BAILEY, MJ .
BRITISH MEDICAL JOURNAL, 1979, 1 (6179) :1671-1673
[5]   COMPLICATIONS AND SIDE-EFFECTS ASSOCIATED WITH LARGE-BORE CATHETERS IN THE SUBCLAVIAN AND INTERNAL JUGULAR VEINS [J].
BAMBAUER, R ;
INNIGER, R ;
PIRRUNG, KJ ;
SCHIEL, R ;
DAHLEM, R .
ARTIFICIAL ORGANS, 1994, 18 (04) :318-321
[6]  
Barrow GI., 1993, COWAN STEELS MANUAL, V3th
[7]   TREATMENT OF ACUTE RESPIRATORY-FAILURE BY EXTRACORPOREAL CARBON-DIOXIDE ELIMINATION PERFORMED WITH A SURFACE HEPARINIZED ARTIFICIAL LUNG [J].
BINDSLEV, L ;
EKLUND, J ;
NORLANDER, O ;
SWEDENBORG, J ;
OLSSON, P ;
NILSSON, E ;
LARM, O ;
GOUDA, I ;
MALMBERG, A ;
SCHOLANDER, E .
ANESTHESIOLOGY, 1987, 67 (01) :117-120
[8]  
BRAY GA, 1990, PRESENT KNOWLEDGE NU, P23
[9]  
Brismar B, 1981, J Hosp Infect, V2, P37, DOI 10.1016/0195-6701(81)90004-9
[10]   A MORPHOLOGICAL-STUDY OF BACTERIAL-COLONIZATION OF INTRAVENOUS CANNULAE [J].
CHEESBROUGH, JS ;
ELLIOTT, TSJ ;
FINCH, RG .
JOURNAL OF MEDICAL MICROBIOLOGY, 1985, 19 (02) :149-157